Need Help? - Call us at (888) 702-1513 or email us at support@labequipmentdirect.com.

Tuttnauer Autoclave Valueklave 1730 Steam 7 X 13 Inch Chamber Single Door

Valueklave  |  SKU: 179515
Sale price $4,362.61 Regular price $5,889.52
Shipping calculated at checkout.

FREE SHIPPING in the Continental US


SETTING UP A NEW LAB?

SAVE TIME AND MONEY—TALK TO A LAB EQUIPMENT EXPERT NOW!

Call us at 1 (888) 702-1513 for a FREE CONSULTATION and personalized quote.

Description

Compact Benchtop Steam Autoclave for Medical, Dental, and Laboratory Instrument Sterilization

The Tuttnauer Valueklave 1730 Benchtop Autoclave is a compact steam sterilizer designed for medical offices, dental clinics, veterinary practices, and small laboratories that require reliable sterilization of instruments and tools.

Manufactured by Tuttnauer USA, a globally recognized leader in sterilization technology, the Valueklave 1730 provides dependable sterilization using pressurized steam to eliminate bacteria, viruses, fungi, and spores from instruments and equipment.

What the Valueklave 1730 Autoclave Is Used For

Steam autoclaves sterilize instruments by exposing them to pressurized saturated steam at high temperatures, destroying microorganisms and preventing contamination.

The Tuttnauer Valueklave 1730 autoclave is commonly used to sterilize:

  • Dental instruments and tools
  • Surgical and medical instruments
  • Veterinary equipment
  • Laboratory glassware and tools
  • Stainless steel instruments and reusable clinical devices

Its quick cycle times and compact design make it ideal for facilities that need reliable daily sterilization without large equipment installations.

What the Valueklave 1730 Autoclave Is Used For

Steam autoclaves sterilize instruments by exposing them to pressurized saturated steam at high temperatures, destroying microorganisms and preventing contamination.

The Tuttnauer Valueklave 1730 autoclave is commonly used to sterilize:

  • Dental instruments and tools
  • Surgical and medical instruments
  • Veterinary equipment
  • Laboratory glassware and tools
  • Stainless steel instruments and reusable clinical devices

Its quick cycle times and compact design make it ideal for facilities that need reliable daily sterilization without large equipment installations.

Technical Specifications

Specification Details
Product Name Valueklave 1730 Benchtop Autoclave
Brand Valueklave 1730
Manufacturer Tuttnauer USA
Manufacturer Number VALUEKLAVE
McKesson Number 179515
Application Benchtop Autoclave
Sterilization Type Steam
Chamber Dimensions 7 × 13 inches
Chamber Capacity 2 Gallons
Cassette Capacity 2 Full Cassettes
Number of Trays 3 Trays
Tray Dimensions 4/5 × 1-3/5 × 4-3/4 inches
Door Type Single Door
Overall Dimensions 12 × 17-2/5 × 18 inches
Sterilization Cycle Time Cold: 16 minutes / Hot: 11 minutes
Buy American Act (BAA) Compliant No
Trade Agreement Act (TAA) Compliant No
UNSPSC Code 42281508
Country of Origin Unknown

 

Who Should Use the Valueklave 1730 Autoclave

The Tuttnauer Valueklave 1730 Benchtop Autoclave is designed for facilities that require reliable sterilization in a compact and cost-efficient system.

Common users include:

  • Dental clinics
  • Medical offices
  • Veterinary practices
  • Surgical centers
  • Research laboratories
  • Small diagnostic labs

The compact size and quick cycle times make this autoclave particularly useful for facilities with limited space or high instrument turnover.

How Steam Autoclaves Sterilize Instruments

Steam autoclaves sterilize equipment by using pressurized saturated steam at high temperatures, typically between 250°F and 273°F.

The sterilization process includes:

  1. Generating steam inside a sealed chamber
  2. Raising the chamber pressure and temperature
  3. Maintaining sterilization temperature for a defined cycle time
  4. Destroying microorganisms by denaturing proteins and disrupting cell structures

This method is considered one of the most effective sterilization techniques for medical and laboratory instruments.

How Steam Autoclaves Sterilize Instruments

Steam autoclaves sterilize equipment by using pressurized saturated steam at high temperatures, typically between 250°F and 273°F.

The sterilization process includes:

  1. Generating steam inside a sealed chamber
  2. Raising the chamber pressure and temperature
  3. Maintaining sterilization temperature for a defined cycle time
  4. Destroying microorganisms by denaturing proteins and disrupting cell structures

This method is considered one of the most effective sterilization techniques for medical and laboratory instruments.

📚 Frequently Asked Questions (FAQs)

What is the capacity of the Valueklave 1730 autoclave?

The autoclave features a 2-gallon chamber with dimensions of 7 × 13 inches.

How long does a sterilization cycle take?

Cycle times are approximately 16 minutes when starting cold and 11 minutes when the chamber is already hot.

Can this autoclave sterilize wrapped instruments?

Yes. The Valueklave 1730 supports sterilization of both wrapped and unwrapped instruments.

How many trays are included with the unit?

The unit includes 3 sterilization trays for organizing instruments during sterilization.

Is the autoclave safe to operate?

Yes. The system includes a double safety locking mechanism that prevents the door from opening while the chamber is pressurized.

Does the autoclave shut off automatically?

Yes. The system features automatic shutoff at the end of both sterilization and drying cycles.

Is this autoclave suitable for dental clinics?

Yes. The Valueklave 1730 is widely used in dental clinics, medical offices, veterinary practices, and small laboratories.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.