Need Help? - Call us at (888) 702-1513 or email us at support@labequipmentdirect.com.

Tuttnauer USA Pre / Post Vacuum Autoclave – 85L Class B Steam Sterilizer with Automatic Door

Tuttnauer USA  |  SKU: 1229476
Sale price $43,317.01 Regular price $58,477.96
Shipping calculated at checkout.

FREE SHIPPING in the Continental US


SETTING UP A NEW LAB?

SAVE TIME AND MONEY—TALK TO A LAB EQUIPMENT EXPERT NOW!

Call us at 1 (888) 702-1513 for a FREE CONSULTATION and personalized quote.

Description

Advanced Pre/Post Vacuum Sterilization for Surgery Centers & Clinics

The Tuttnauer 3870HSG-WS autoclave is a hospital-grade Class B pre/post vacuum sterilizer designed for surgery centers and high-volume clinics. With an 85-liter chamber, automatic locking door, and built-in steam generator, it delivers fast, compliant sterilization for wrapped, porous, and complex instruments.

What This Autoclave Does

The 3870HSG-WS uses pre-vacuum and post-vacuum steam sterilization (Class B) to remove air before sterilization and ensure deep steam penetration.

This allows it to:

  • Sterilize wrapped instruments, textiles, and complex loads
  • Deliver fast and consistent cycle performance
  • Maintain sterilization integrity in high-demand environments
  • Support regulated workflows requiring documentation and traceability

Key Capabilities

  • Class B Pre / Post Vacuum Sterilization
    Ensures full air removal and deep steam penetration for maximum sterilization effectiveness.
  • 85L Large-Capacity Chamber
    Built for high-throughput environments handling multiple loads daily.
  • Automatic Locking Door
    Secures the chamber during operation for enhanced safety and ease of use.
  • Built-In Steam Generator (HSG)
    Enables independent operation without reliance on external steam supply.
  • Continuous 24/7 Operation
    Designed for facilities that require uninterrupted sterilization cycles.
  • Flexible Installation Options
    Can operate as a standalone system or connect to building utilities.
  • Automatic Data Recording
    Stores cycle data directly to a networked PC for tracking and compliance.
  • PDF Report Generation
    Simplifies documentation for audits, inspections, and internal records.
  • Multicolor LCD Display
    Clear and intuitive interface for monitoring cycle status and system performance.

Technical Specifications

Specification Details
Model 3870HSG-WS-230-D
Chamber Dimensions 15-1/5" x 30"
Chamber Volume 85 Liters
Sterilization Type Steam (Pre/Post Vacuum – Class B)
Door Type Automatic Locking Door
Number of Trays 2 Trays
Tray Dimensions (Small) 1" x 11-1/3" x 26-2/3"
Tray Dimensions (Large) 1" x 13-4/5" x 26-2/3"
Overall Dimensions 28-2/5" x 53-4/5" x 46-1/2"
Weight 397 lbs
Voltage / Frequency 3 Phase, 230V, 60Hz
Current 25 Amp
UNSPSC Code 42281508
Manufacturer Tuttnauer USA
Application Pre / Post Vacuum Autoclave

 

Is This the Right Autoclave for Your Facility?

Best Fit

  • Ambulatory surgery centers (ASC)
  • Large medical or dental clinics with high daily volume
  • Facilities sterilizing wrapped, porous, or hollow instruments
  • Teams requiring Class B compliance-level sterilization
  • Operations needing 24/7 continuous performance
  • Clinics requiring cycle tracking and documentation

Not Ideal For

  • Small clinics with low sterilization demand
  • Basic instrument sterilization (unwrapped only)
  • Locations without 3-phase power
  • Buyers needing a compact or benchtop unit
  • Budget-sensitive setups needing entry-level equipment

Compliance & Safety

  • Hospital-grade Class B sterilization standard
  • Designed for regulated clinical environments
  • Automatic locking door for operational safety
  • Built-in system protections for consistent performance
  • Supports cycle tracking and documentation requirements

Installation & Requirements

Before purchasing, confirm:

  • 3-phase 230V electrical supply
  • Adequate floor space and ventilation clearance
  • Optional connections:

    • Distilled water

    • Tap water

    • Drain system

  • Network access for data recording and reporting

Why Facilities Choose the 3870HSG-WS

  • True hospital-grade Class B sterilization
  • Handles high-volume and complex loads
  • Built for continuous operation environments
  • Integrated data tracking and reporting
  • Trusted Tuttnauer reliability

📚 Frequently Asked Questions (FAQs)

What makes this a Class B autoclave?

It uses pre and post vacuum cycles to remove air and allow steam to fully penetrate wrapped and complex instruments.

Is this suitable for surgery centers?

Yes. It is specifically designed for ASC environments and high-volume clinical use.

Can it operate without building utilities?

Yes. The built-in steam generator allows independent operation if needed.

Does it support compliance documentation?

Yes. It includes automatic cycle recording and PDF report generation.

What type of power does it require?

It requires 3-phase 230V power, standard for hospital-grade equipment.

When should I choose a smaller autoclave instead?

Have low daily sterilization needs Need a compact benchtop unit Do not require Class B performance

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.