Need Help? - Call us at (888) 702-1513 or email us at support@labequipmentdirect.com.

Siemens DCA Vantage Diabetes Management Analyzer – CLIA Waived HbA1c & A:C Ratio System

DCA Vantage  |  SKU: 641021
Sale price $4,664.94 Regular price $6,297.66
Shipping calculated at checkout.

FREE SHIPPING in the Continental US


SETTING UP A NEW LAB?

SAVE TIME AND MONEY—TALK TO A LAB EQUIPMENT EXPERT NOW!

Call us at 1 (888) 702-1513 for a FREE CONSULTATION and personalized quote.

Description

CLIA Waived HbA1c Analyzer for Fast Point-of-Care Diabetes Testing

The Siemens DCA Vantage® Diabetes Management Analyzer is a compact benchtop system designed for point-of-care HbA1c and urine albumin-to-creatinine (A:C) ratio testing.

It uses immunoassay cartridge technology with automatic calibration to deliver clinically accurate results in minutes, helping healthcare providers assess long-term glucose control and detect early kidney disease using minimal sample volumes.

Who This Diabetes Analyzer Is For

Best For:

  • Physician offices and primary care clinics
  • Endocrinology and diabetes care centers
  • Point-of-care testing environments
  • Clinics requiring CLIA waived HbA1c testing
  • Facilities focused on fast patient turnaround

Not Ideal For:

  • High-volume centralized laboratories
  • Multi-analyte automated lab systems

Core Tests and Clinical Value

HbA1c Testing

Provides HbA1c results in approximately 6 minutes, enabling clinicians to evaluate long-term glucose control and make immediate treatment decisions.

Albumin-to-Creatinine (A:C) Ratio Testing (7-Minute Results)

Detects early kidney damage in diabetic patients, supporting early intervention and improved patient outcomes.

Comprehensive Diabetes Monitoring Panel

Supports:

  • Hemoglobin A1c
  • Albumin
  • Microalbumin
  • Creatinine
  • Albumin-to-Creatinine ratio

Speed and Sample Efficiency

  • HbA1c Results: ~6 minutes
  • A:C Ratio Results: ~7 minutes
  • Sample Volume:
    • 1 µL whole blood (HbA1c)
    • 40 µL urine (A:C)

Workflow and Ease of Use

Cartridge-Based Testing with Automatic Calibration

  • Each test uses an immunoassay cartridge with a lot-specific calibration card
  • Eliminates manual calibration and reduces user error

Simple, Guided Operation

  • Color touchscreen interface
  • Barcode reader for patient and sample identification
  • Minimal training required for operation

Built-In Printing and Data Handling

  • Onboard thermal printer provides immediate results
  • Electronic transmission to LIS or EMR systems reduces transcription errors

Data Management and Connectivity

  • Stores up to 4,000 patient and control records
  • Supports up to 1,000 operator IDs
  • Enables seamless integration with laboratory and clinical systems

Technical Specifications

Specification Details
Brand DCA Vantage®
Manufacturer Siemens
Application Diabetes Management Analyzer
Analyzer Type Benchtop
CLIA Classification Waived (HbA1c), Moderate Complexity (A:C)
Sample Types Whole Blood, Urine
Sample Volume 1 µL (blood), 40 µL (urine)
Test Menu HbA1c, Albumin, Creatinine, A:C Ratio
Time to Results 6 min (HbA1c), 7 min (A:C)
Display Color Touchscreen
Printer Built-in Thermal Printer
Dimensions 9" x 10" x 11-1/2"
Weight 9 lbs
Power 100–240 VAC
Memory 4,000 patient records
UNSPSC Code 41115819
BAA Compliant No
TAA Compliant Yes

 

How the Siemens DCA Vantage® Analyzer Works

  • Collect Sample
    Obtain a small blood or urine sample.
  • Insert Test Cartridge
    Load the immunoassay cartridge with calibration card.
  • Start Analysis
    The analyzer automatically processes the sample.
  • View Results
    Results are displayed and printed within minutes.

Clinical Applications

  • Diabetes diagnosis and monitoring
  • Glycemic control assessment (HbA1c)
  • Early detection of diabetic kidney disease
  • Routine screening in primary care settings
  • Point-of-care patient management

Compliance and Laboratory Standards

  • CLIA Waived for HbA1c testing
  • CLIA Moderate Complexity for A:C testing
  • Designed for point-of-care and clinical environments
  • Supports standardized diabetes monitoring protocols

📚 Frequently Asked Questions (FAQs)

What is the DCA Vantage® analyzer used for?

It is used for HbA1c and urine A:C ratio testing to monitor diabetes and kidney function.

How fast are HbA1c results?

Results are available in approximately 6 minutes.

How much sample is required?

Only 1 µL of whole blood is needed for HbA1c testing.

Is this analyzer CLIA waived?

Yes, for HbA1c testing; A:C testing is moderate complexity.

Can it detect kidney disease?

Yes, through microalbumin and A:C ratio testing.

Does it require calibration?

No manual calibration is required; cartridges include automatic calibration.

Can results be printed?

Yes, it includes a built-in thermal printer.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.