Need Help? - Call us at (888) 702-1513 or email us at support@labequipmentdirect.com.

Siemens BFT II Coagulation Analyzer – Benchtop CLIA Non-Waived Hemostasis System

BFT II  |  SKU: 1060832
Sale price $10,350.00 Regular price $13,972.50
Shipping calculated at checkout.

FREE SHIPPING in the Continental US


SETTING UP A NEW LAB?

SAVE TIME AND MONEY—TALK TO A LAB EQUIPMENT EXPERT NOW!

Call us at 1 (888) 702-1513 for a FREE CONSULTATION and personalized quote.

Description

Compact Hemostasis Analyzer for Accurate Blood Clotting Tests

The Siemens BFT II Coagulation Analyzer is a compact benchtop system designed to perform automated coagulation testing, including PT (Prothrombin Time), APTT (Activated Partial Thromboplastin Time), fibrinogen, and thrombosis-related assays.

It uses pre-defined assay protocols, dual measuring channels, and temperature-controlled incubation to analyze blood clotting function, providing accurate and reproducible results for clinical laboratories and diagnostic settings.

Who This Coagulation Analyzer Is For

Best For:

  • Clinical and hospital laboratories
  • Diagnostic labs performing hemostasis testing
  • Laboratories requiring CLIA non-waived systems
  • Small to medium-volume testing environments
  • Labs needing compact benchtop analyzers

Not Ideal For:

  • CLIA-waived or point-of-care testing
  • High-throughput, large-scale reference laboratories

Core Testing Capabilities and Why They Matter

Comprehensive Coagulation Test Menu

Supports key hemostasis assays, including:

  • Prothrombin Time (PT)
  • Activated Partial Thromboplastin Time (APTT)
  • Fibrinogen testing
  • Thrombin time
  • Factor deficiency assays
  • Lupus anticoagulant testing
  • Thrombosis risk evaluation

These tests are essential for diagnosing clotting disorders and monitoring anticoagulant therapy.

Throughput and Performance

  • PT Throughput: Up to 60 tests per hour
  • APTT Throughput: Up to 30 tests per hour
  • Dual measuring channels enable simultaneous testing

This allows laboratories to improve turnaround times while maintaining accuracy.

Workflow and Sample Handling

Dual Measuring Channels

Allows two tests to run simultaneously, increasing efficiency and reducing delays in result reporting.

Low Sample Volume Testing

Supports half-volume and single cuvette testing, making it suitable for limited or sensitive samples.

Manual Pipetting with Error Reduction

  • Light protection cap ensures proper pipetting workflow
  • Channel remains closed until cuvette insertion

This reduces user errors and improves consistency.

Automation and System Features

Pre-Defined Assays with Stored Reference Curves

  • Eliminates manual calibration
  • Ensures standardized and reproducible results

Automatic Result Calculations

Automatically calculates:

  • PT (seconds)
  • % of normal
  • INR
  • Fibrinogen (mg/dL or g/L)

Temperature-Controlled Incubation Block

Maintains stable conditions for reagents and samples, ensuring accurate test results.

Onboard Capacity

  • Supports up to 30 cuvettes
  • Includes reagent mixer for consistent preparation

Result Handling and Output

Built-In Thermal Printer

  • Prints test results directly
  • Simplifies documentation and reporting

Automatic Timing System

  • Built-in timer with automatic start/stop
  • Ensures precise measurement intervals

Technical Specifications

Specification Details
Brand BFT II
Manufacturer Siemens
Application Coagulation Analyzer
Analyzer Type Benchtop
Throughput 60 tests/hr (PT) / 30 tests/hr (APTT)
Sample Type Blood
Output Thermal Printer
Dimensions 100 x 200 x 300 mm
Weight 3.8 kg
CLIA Classification Non-Waived
Reagent Capacity 4 reagents with mixer
Cuvette Capacity Up to 30
UNSPSC Code 41115809
BAA Compliant No
TAA Compliant Yes

 

How the Siemens BFT II Coagulation Analyzer Works

  • Prepare Blood Sample
    Collect and prepare patient samples.
  • Load Reagents and Cuvettes
    Insert reagents and cuvettes into the analyzer.
  • Pipette Sample
    Manually pipette the sample into the cuvette.
  • Start Analysis
    The analyzer performs automated coagulation testing.
  • View and Print Results
    Results are calculated and printed automatically.

Clinical Applications

  • Diagnosis of coagulation disorders
  • Monitoring anticoagulant therapy
  • Thrombosis risk assessment
  • Hemostasis testing in clinical labs
  • Factor deficiency evaluation

Compliance and Laboratory Standards

  • Designed for CLIA non-waived testing environments
  • Supports standardized coagulation testing protocols
  • Ensures consistent and reproducible diagnostic results

📚 Frequently Asked Questions (FAQs)

What is a coagulation analyzer used for?

It measures blood clotting parameters to diagnose and monitor coagulation disorders.

What tests can the BFT II perform?

It performs PT, APTT, fibrinogen, thrombin time, and thrombosis-related assays.

What does CLIA non-waived mean?

It indicates moderate to high complexity testing requiring certified laboratory personnel.

What is the throughput of this analyzer?

It processes up to 60 PT tests/hour and 30 APTT tests/hour.

Does it support simultaneous testing?

Yes, dual channels allow two tests to run at the same time.

How are results recorded?

Results are printed using the built-in thermal printer.

Does it require large sample volumes?

No, it supports low-volume testing.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.