{"product_id":"tuttnauer-t-top-11s-benchtop-autoclave","title":"Tuttnauer T Top 11S Benchtop Autoclave – 27L Class S Steam Sterilizer","description":"\u003ch2\u003eAdvanced 27L Class S Benchtop Steam Autoclave for Clinical and Laboratory Sterilization\u003c\/h2\u003e\n\u003cp data-start=\"470\" data-end=\"692\"\u003eThe Tuttnauer T Top 11S Benchtop Autoclave is a Class S steam sterilizer designed for dental clinics, medical practices, and laboratory environments that require reliable sterilization of instruments and equipment.\u003c\/p\u003e\n\u003cp data-start=\"694\" data-end=\"947\"\u003eManufactured by Tuttnauer USA, a trusted global leader in sterilization technology, the T Top 11S provides dependable sterilization performance using high-temperature pressurized steam to eliminate bacteria, viruses, fungi, and microbial spores.\u003c\/p\u003e\n\u003ch2 data-section-id=\"l8bckt\" data-start=\"1628\" data-end=\"1670\"\u003eWhat the T Top 11S Autoclave Is Used For\u003c\/h2\u003e\n\u003cp data-start=\"1672\" data-end=\"1839\"\u003eA \u003cstrong data-start=\"1674\" data-end=\"1764\"\u003ebenchtop autoclave sterilizes instruments using pressurized steam at high temperatures\u003c\/strong\u003e, effectively destroying microorganisms and ensuring safe instrument reuse.\u003c\/p\u003e\n\u003cp data-start=\"1841\" data-end=\"1917\"\u003eThe \u003cstrong data-start=\"1845\" data-end=\"1886\"\u003eTuttnauer T Top 11S Class S autoclave\u003c\/strong\u003e is commonly used to sterilize:\u003c\/p\u003e\n\u003cul data-start=\"1919\" data-end=\"2152\"\u003e\n\u003cli data-section-id=\"1rrw370\" data-start=\"1919\" data-end=\"1960\"\u003eDental instruments and surgical tools\u003c\/li\u003e\n\u003cli data-section-id=\"1caozc3\" data-start=\"1961\" data-end=\"2008\"\u003eMedical equipment used in clinical settings\u003c\/li\u003e\n\u003cli data-section-id=\"1lz6zr0\" data-start=\"2009\" data-end=\"2051\"\u003eLaboratory instruments and metal tools\u003c\/li\u003e\n\u003cli data-section-id=\"9n4yjm\" data-start=\"2052\" data-end=\"2106\"\u003eGlassware and stainless steel laboratory equipment\u003c\/li\u003e\n\u003cli data-section-id=\"16xme1x\" data-start=\"2107\" data-end=\"2152\"\u003eGeneral clinical and research instruments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"u0ybrq\" data-start=\"2324\" data-end=\"2338\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2340\" data-end=\"2478\"\u003e\n\u003cstrong data-start=\"2340\" data-end=\"2372\"\u003eClass S Steam Sterilization:\u003c\/strong\u003e\u003cbr data-start=\"2372\" data-end=\"2375\"\u003eReliable sterilization using high-temperature pressurized steam for medical and laboratory instruments.\u003c\/li\u003e\n\u003cli data-start=\"2480\" data-end=\"2629\"\u003e\n\u003cstrong data-start=\"2480\" data-end=\"2516\"\u003eLarge 27 Liter Chamber Capacity:\u003c\/strong\u003e\u003cbr data-start=\"2516\" data-end=\"2519\"\u003eThe spacious chamber allows multiple instruments to be sterilized in one cycle, improving workflow efficiency.\u003c\/li\u003e\n\u003cli data-start=\"2631\" data-end=\"2754\"\u003e\n\u003cstrong data-start=\"2631\" data-end=\"2657\"\u003eStand-Alone Operation:\u003c\/strong\u003e\u003cbr data-start=\"2657\" data-end=\"2660\"\u003eRequires only an electrical connection, allowing easy installation in clinics or laboratories.\u003c\/li\u003e\n\u003cli data-start=\"2756\" data-end=\"2870\"\u003e\n\u003cstrong data-start=\"2756\" data-end=\"2792\"\u003eIntuitive Touchscreen Interface:\u003c\/strong\u003e\u003cbr data-start=\"2792\" data-end=\"2795\"\u003eUser-friendly touchscreen controls simplify cycle selection and monitoring.\u003c\/li\u003e\n\u003cli data-start=\"2872\" data-end=\"2986\"\u003e\n\u003cstrong data-start=\"2872\" data-end=\"2901\"\u003eVersatile Cycle Programs:\u003c\/strong\u003e\u003cbr data-start=\"2901\" data-end=\"2904\"\u003eMultiple sterilization cycle options support different instrument types and loads.\u003c\/li\u003e\n\u003cli data-start=\"2988\" data-end=\"3116\"\u003e\n\u003cstrong data-start=\"2988\" data-end=\"3017\"\u003eBuilt-In USB Data Logger:\u003c\/strong\u003e\u003cbr data-start=\"3017\" data-end=\"3020\"\u003eAllows digital storage and transfer of sterilization cycle records for compliance documentation.\u003c\/li\u003e\n\u003cli data-start=\"3118\" data-end=\"3234\"\u003e\n\u003cstrong data-start=\"3118\" data-end=\"3150\"\u003eWi-Fi Monitoring Capability:\u003c\/strong\u003e\u003cbr data-start=\"3150\" data-end=\"3153\"\u003eEnables remote monitoring of sterilization cycles through smartphones or tablets.\u003c\/li\u003e\n\u003cli data-start=\"3236\" data-end=\"3357\"\u003e\n\u003cstrong data-start=\"3236\" data-end=\"3271\"\u003eInternal Memory for 500 Cycles:\u003c\/strong\u003e\u003cbr data-start=\"3271\" data-end=\"3274\"\u003eStores sterilization cycle history digitally for convenient tracking and reporting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"zjxypn\" data-start=\"3364\" data-end=\"3390\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3392\" data-end=\"3928\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3392\" data-end=\"3419\"\u003e\n\u003ctr data-start=\"3392\" data-end=\"3419\"\u003e\n\u003cth data-start=\"3392\" data-end=\"3408\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3408\" data-end=\"3419\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3430\" data-end=\"3928\"\u003e\n\u003ctr data-start=\"3430\" data-end=\"3477\"\u003e\n\u003ctd data-start=\"3430\" data-end=\"3445\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"3445\" data-end=\"3477\" data-col-size=\"sm\"\u003eT Top 11S Benchtop Autoclave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3478\" data-end=\"3506\"\u003e\n\u003ctd data-start=\"3478\" data-end=\"3486\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3486\" data-end=\"3506\" data-col-size=\"sm\"\u003eT Top 11 Class S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3507\" data-end=\"3539\"\u003e\n\u003ctd data-start=\"3507\" data-end=\"3522\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"3522\" data-end=\"3539\" data-col-size=\"sm\"\u003eTuttnauer USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3540\" data-end=\"3580\"\u003e\n\u003ctd data-start=\"3540\" data-end=\"3562\" data-col-size=\"sm\"\u003eManufacturer Number\u003c\/td\u003e\n\u003ctd data-start=\"3562\" data-end=\"3580\" data-col-size=\"sm\"\u003eT-TOP 11S 110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3581\" data-end=\"3610\"\u003e\n\u003ctd data-start=\"3581\" data-end=\"3599\" data-col-size=\"sm\"\u003eMcKesson Number\u003c\/td\u003e\n\u003ctd data-start=\"3599\" data-end=\"3610\" data-col-size=\"sm\"\u003e1266312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3611\" data-end=\"3647\"\u003e\n\u003ctd data-start=\"3611\" data-end=\"3625\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"3625\" data-end=\"3647\" data-col-size=\"sm\"\u003eBenchtop Autoclave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3648\" data-end=\"3680\"\u003e\n\u003ctd data-start=\"3648\" data-end=\"3671\" data-col-size=\"sm\"\u003eSterilization Method\u003c\/td\u003e\n\u003ctd data-start=\"3671\" data-end=\"3680\" data-col-size=\"sm\"\u003eSteam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3681\" data-end=\"3720\"\u003e\n\u003ctd data-start=\"3681\" data-end=\"3702\" data-col-size=\"sm\"\u003eChamber Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"3702\" data-end=\"3720\" data-col-size=\"sm\"\u003e11 × 18 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3721\" data-end=\"3753\"\u003e\n\u003ctd data-start=\"3721\" data-end=\"3740\" data-col-size=\"sm\"\u003eChamber Capacity\u003c\/td\u003e\n\u003ctd data-start=\"3740\" data-end=\"3753\" data-col-size=\"sm\"\u003e27 Liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3754\" data-end=\"3782\"\u003e\n\u003ctd data-start=\"3754\" data-end=\"3774\" data-col-size=\"sm\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3774\" data-end=\"3782\"\u003e110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3783\" data-end=\"3809\"\u003e\n\u003ctd data-start=\"3783\" data-end=\"3797\" data-col-size=\"sm\"\u003eUNSPSC Code\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3797\" data-end=\"3809\"\u003e42281508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3810\" data-end=\"3851\"\u003e\n\u003ctd data-start=\"3810\" data-end=\"3845\" data-col-size=\"sm\"\u003eBuy American Act (BAA) Compliant\u003c\/td\u003e\n\u003ctd data-start=\"3845\" data-end=\"3851\" data-col-size=\"sm\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3852\" data-end=\"3896\"\u003e\n\u003ctd data-start=\"3852\" data-end=\"3890\" data-col-size=\"sm\"\u003eTrade Agreement Act (TAA) Compliant\u003c\/td\u003e\n\u003ctd data-start=\"3890\" data-end=\"3896\" data-col-size=\"sm\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3897\" data-end=\"3928\"\u003e\n\u003ctd data-start=\"3897\" data-end=\"3917\" data-col-size=\"sm\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-start=\"3917\" data-end=\"3928\" data-col-size=\"sm\"\u003eUnknown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 data-section-id=\"3rfagr\" data-start=\"3935\" data-end=\"3975\"\u003eWho Should Use the T Top 11S Autoclave\u003c\/h2\u003e\n\u003cp data-start=\"3977\" data-end=\"4119\"\u003eThe \u003cstrong data-start=\"3981\" data-end=\"4022\"\u003eTuttnauer T Top 11S Class S Autoclave\u003c\/strong\u003e is ideal for facilities that require reliable sterilization of instruments and laboratory tools.\u003c\/p\u003e\n\u003cp data-start=\"4121\" data-end=\"4142\"\u003eCommon users include:\u003c\/p\u003e\n\u003cul data-start=\"4144\" data-end=\"4295\"\u003e\n\u003cli data-section-id=\"kehnbj\" data-start=\"4144\" data-end=\"4162\"\u003eDental clinics\u003c\/li\u003e\n\u003cli data-section-id=\"d9q3g2\" data-start=\"4163\" data-end=\"4182\"\u003eMedical clinics\u003c\/li\u003e\n\u003cli data-section-id=\"3o4pkt\" data-start=\"4183\" data-end=\"4207\"\u003eVeterinary practices\u003c\/li\u003e\n\u003cli data-section-id=\"1sfq8ju\" data-start=\"4208\" data-end=\"4235\"\u003eDiagnostic laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1np67ex\" data-start=\"4236\" data-end=\"4264\"\u003eUniversity research labs\u003c\/li\u003e\n\u003cli data-section-id=\"roqxn3\" data-start=\"4265\" data-end=\"4295\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"19g0djw\" data-start=\"4457\" data-end=\"4501\"\u003eHow Steam Autoclaves Sterilize Instruments\u003c\/h2\u003e\n\u003cp data-start=\"4503\" data-end=\"4630\"\u003eSteam autoclaves sterilize instruments using \u003cstrong data-start=\"4548\" data-end=\"4629\"\u003epressurized saturated steam at temperatures typically between 250°F and 273°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"4632\" data-end=\"4667\"\u003eThe sterilization process works by:\u003c\/p\u003e\n\u003col data-start=\"4669\" data-end=\"4886\"\u003e\n\u003cli data-section-id=\"18c2vv1\" data-start=\"4669\" data-end=\"4720\"\u003eIntroducing pressurized steam into the chamber\u003c\/li\u003e\n\u003cli data-section-id=\"fhptol\" data-start=\"4721\" data-end=\"4797\"\u003eMaintaining a high sterilization temperature for a specified cycle time\u003c\/li\u003e\n\u003cli data-section-id=\"6g6vmr\" data-start=\"4798\" data-end=\"4886\"\u003eDestroying microorganisms by denaturing proteins and disrupting cellular structures\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-section-id=\"hhn6i8\" data-start=\"5051\" data-end=\"5084\"\u003eWhy Choose Tuttnauer Autoclaves\u003c\/h2\u003e\n\u003cp data-start=\"5086\" data-end=\"5258\"\u003eTuttnauer is a globally recognized manufacturer of \u003cstrong data-start=\"5137\" data-end=\"5187\"\u003emedical and laboratory sterilization equipment\u003c\/strong\u003e, supplying hospitals, laboratories, and research facilities worldwide.\u003c\/p\u003e\n\u003cp data-start=\"5260\" data-end=\"5295\"\u003eThe \u003cstrong data-start=\"5264\" data-end=\"5287\"\u003eT Top 11S Autoclave\u003c\/strong\u003e offers:\u003c\/p\u003e\n\u003cul data-start=\"5297\" data-end=\"5539\"\u003e\n\u003cli data-section-id=\"6a9j6l\" data-start=\"5297\" data-end=\"5341\"\u003eReliable steam sterilization performance\u003c\/li\u003e\n\u003cli data-section-id=\"1qculo1\" data-start=\"5342\" data-end=\"5392\"\u003eLarge chamber capacity for efficient workflows\u003c\/li\u003e\n\u003cli data-section-id=\"1qqwx2k\" data-start=\"5393\" data-end=\"5438\"\u003eWi-Fi connectivity and digital monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"gdhkir\" data-start=\"5439\" data-end=\"5493\"\u003eBuilt-in data logging for compliance documentation\u003c\/li\u003e\n\u003cli data-section-id=\"12o4vn0\" data-start=\"5494\" data-end=\"5539\"\u003eSimple touchscreen operation for easy use\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"T-Top","offers":[{"title":"Default Title","offer_id":44261764628573,"sku":"1266312","price":10108.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/tuttnauer-t-top-11s-benchtop-autoclave-27l-class-s-steam-sterilizer-1266312-1227080583.png?v=1773344590","url":"https:\/\/labequipmentdirect.com\/products\/tuttnauer-t-top-11s-benchtop-autoclave","provider":"Lab Equipment Direct","version":"1.0","type":"link"}