{"product_id":"tuttnauer-t-top-11b-benchtop-autoclave","title":"Tuttnauer T-Top 11B Benchtop Autoclave 21L Class B Steam Sterilizer","description":"\u003ch2\u003eHigh-Performance Steam Sterilization for Modern Medical and Lab Environments\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong data-start=\"497\" data-end=\"539\"\u003eTuttnauer T-Top 11B Benchtop Autoclave\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"562\" data-end=\"666\"\u003eClass B steam sterilizer designed for dental clinics, medical practices, and laboratory environments\u003c\/strong\u003e that require reliable sterilization of complex instrument loads.\u003c\/p\u003e\n\u003cp data-start=\"733\" data-end=\"1045\"\u003eManufactured by \u003cstrong data-start=\"749\" data-end=\"766\"\u003eTuttnauer USA\u003c\/strong\u003e, a globally trusted sterilization equipment provider, the T-Top 11B features advanced \u003cstrong data-start=\"853\" data-end=\"908\"\u003epre-vacuum and post-vacuum sterilization technology\u003c\/strong\u003e, allowing it to sterilize \u003cstrong data-start=\"935\" data-end=\"1013\"\u003ewrapped instruments, unwrapped tools, porous materials, and hollow devices\u003c\/strong\u003e with precision and reliability.\u003c\/p\u003e\n\u003ch2 data-section-id=\"bvb2fl\" data-start=\"1724\" data-end=\"1766\"\u003eWhat the T-Top 11B Autoclave Is Used For\u003c\/h2\u003e\n\u003cp data-start=\"1768\" data-end=\"1958\"\u003eA \u003cstrong data-start=\"1770\" data-end=\"1870\"\u003ebenchtop autoclave sterilizes instruments and materials using high-temperature pressurized steam\u003c\/strong\u003e, effectively eliminating microorganisms including bacteria, viruses, fungi, and spores.\u003c\/p\u003e\n\u003cp data-start=\"1960\" data-end=\"2036\"\u003eThe \u003cstrong data-start=\"1964\" data-end=\"2005\"\u003eTuttnauer T-Top 11B Class B autoclave\u003c\/strong\u003e is commonly used to sterilize:\u003c\/p\u003e\n\u003cul data-start=\"2038\" data-end=\"2238\"\u003e\n\u003cli data-section-id=\"1qntdtz\" data-start=\"2038\" data-end=\"2073\"\u003eDental and surgical instruments\u003c\/li\u003e\n\u003cli data-section-id=\"1y3vyf5\" data-start=\"2074\" data-end=\"2108\"\u003eLaboratory equipment and tools\u003c\/li\u003e\n\u003cli data-section-id=\"x92m9j\" data-start=\"2109\" data-end=\"2135\"\u003eHollow medical devices\u003c\/li\u003e\n\u003cli data-section-id=\"yny66z\" data-start=\"2136\" data-end=\"2195\"\u003ePorous materials such as fabrics or wrapped instruments\u003c\/li\u003e\n\u003cli data-section-id=\"1jgz5vh\" data-start=\"2196\" data-end=\"2238\"\u003eMetal and glass laboratory instruments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBecause \u003cstrong data-start=\"2248\" data-end=\"2296\"\u003eClass B autoclaves include pre-vacuum phases\u003c\/strong\u003e, they ensure steam penetrates deeply into complex loads, making them suitable for \u003cstrong data-start=\"2379\" data-end=\"2482\"\u003emedical and laboratory sterilization environments that require advanced sterilization capabilities.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"u0ybrq\" data-start=\"2489\" data-end=\"2503\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2505\" data-end=\"2704\"\u003e\n\u003cstrong data-start=\"2505\" data-end=\"2542\"\u003eClass B Sterilization Technology:\u003c\/strong\u003e\u003cbr data-start=\"2542\" data-end=\"2545\"\u003eEquipped with \u003cstrong data-start=\"2559\" data-end=\"2610\"\u003epre-vacuum and post-vacuum sterilization phases\u003c\/strong\u003e, allowing the sterilization of wrapped instruments, porous loads, and hollow medical devices.\u003c\/li\u003e\n\u003cli data-start=\"2706\" data-end=\"2875\"\u003e\n\u003cstrong data-start=\"2706\" data-end=\"2742\"\u003eLarge 21-Liter Chamber Capacity:\u003c\/strong\u003e\u003cbr data-start=\"2742\" data-end=\"2745\"\u003eThe spacious chamber accommodates multiple trays and instruments, improving workflow efficiency for busy clinics and laboratories.\u003c\/li\u003e\n\u003cli data-start=\"2877\" data-end=\"3024\"\u003e\n\u003cstrong data-start=\"2877\" data-end=\"2908\"\u003eShort Sterilization Cycles:\u003c\/strong\u003e\u003cbr data-start=\"2908\" data-end=\"2911\"\u003eOptimized sterilization cycles help reduce turnaround time and maintain productivity in high-demand environments.\u003c\/li\u003e\n\u003cli data-start=\"3026\" data-end=\"3192\"\u003e\n\u003cstrong data-start=\"3026\" data-end=\"3064\"\u003eMulticolour Touchscreen Interface:\u003c\/strong\u003e\u003cbr data-start=\"3064\" data-end=\"3067\"\u003eThe intuitive touchscreen display provides easy navigation with clear icons for selecting and running sterilization programs.\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3342\"\u003e\n\u003cstrong data-start=\"3194\" data-end=\"3227\"\u003eT-Connect Remote Diagnostics:\u003c\/strong\u003e\u003cbr data-start=\"3227\" data-end=\"3230\"\u003eIntegrated \u003cstrong data-start=\"3241\" data-end=\"3263\"\u003eT-Connect software\u003c\/strong\u003e allows remote system monitoring, diagnostics, alerts, and cycle data tracking.\u003c\/li\u003e\n\u003cli data-start=\"3344\" data-end=\"3483\"\u003e\n\u003cstrong data-start=\"3344\" data-end=\"3381\"\u003eWi-Fi Connectivity and USB Ports:\u003c\/strong\u003e\u003cbr data-start=\"3381\" data-end=\"3384\"\u003eBuilt-in Wi-Fi and two USB ports enable connectivity for reporting, monitoring, and system updates.\u003c\/li\u003e\n\u003cli data-start=\"3485\" data-end=\"3616\"\u003e\n\u003cstrong data-start=\"3485\" data-end=\"3513\"\u003ePaperless Documentation:\u003c\/strong\u003e\u003cbr data-start=\"3513\" data-end=\"3516\"\u003eCycle records are stored digitally, simplifying compliance documentation and eliminating paper logs.\u003c\/li\u003e\n\u003cli data-start=\"3618\" data-end=\"3761\"\u003e\n\u003cstrong data-start=\"3618\" data-end=\"3647\"\u003eCompact Ergonomic Design:\u003c\/strong\u003e\u003cbr data-start=\"3647\" data-end=\"3650\"\u003eEngineered to fit comfortably in clinical and laboratory workspaces without sacrificing sterilization capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"zjxypn\" data-start=\"3768\" data-end=\"3794\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3796\" data-end=\"4519\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3796\" data-end=\"3823\"\u003e\n\u003ctr data-start=\"3796\" data-end=\"3823\"\u003e\n\u003cth data-start=\"3796\" data-end=\"3812\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3812\" data-end=\"3823\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3834\" data-end=\"4519\"\u003e\n\u003ctr data-start=\"3834\" data-end=\"3881\"\u003e\n\u003ctd data-start=\"3834\" data-end=\"3849\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"3849\" data-end=\"3881\" data-col-size=\"sm\"\u003eT-Top 11B Benchtop Autoclave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3882\" data-end=\"3910\"\u003e\n\u003ctd data-start=\"3882\" data-end=\"3890\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3890\" data-end=\"3910\" data-col-size=\"sm\"\u003eT-Top 11 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3911\" data-end=\"3943\"\u003e\n\u003ctd data-start=\"3911\" data-end=\"3926\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"3926\" data-end=\"3943\" data-col-size=\"sm\"\u003eTuttnauer USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3944\" data-end=\"3984\"\u003e\n\u003ctd data-start=\"3944\" data-end=\"3966\" data-col-size=\"sm\"\u003eManufacturer Number\u003c\/td\u003e\n\u003ctd data-start=\"3966\" data-end=\"3984\" data-col-size=\"sm\"\u003eT-TOP 11B 110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3985\" data-end=\"4014\"\u003e\n\u003ctd data-start=\"3985\" data-end=\"4003\" data-col-size=\"sm\"\u003eMcKesson Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4003\" data-end=\"4014\"\u003e1267930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4015\" data-end=\"4051\"\u003e\n\u003ctd data-start=\"4015\" data-end=\"4029\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"4029\" data-end=\"4051\" data-col-size=\"sm\"\u003eBenchtop Autoclave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4052\" data-end=\"4082\"\u003e\n\u003ctd data-start=\"4052\" data-end=\"4073\" data-col-size=\"sm\"\u003eSterilization Type\u003c\/td\u003e\n\u003ctd data-start=\"4073\" data-end=\"4082\" data-col-size=\"sm\"\u003eSteam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4083\" data-end=\"4122\"\u003e\n\u003ctd data-start=\"4083\" data-end=\"4104\" data-col-size=\"sm\"\u003eChamber Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"4104\" data-end=\"4122\" data-col-size=\"sm\"\u003e11 × 18 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4123\" data-end=\"4155\"\u003e\n\u003ctd data-start=\"4123\" data-end=\"4142\" data-col-size=\"sm\"\u003eChamber Capacity\u003c\/td\u003e\n\u003ctd data-start=\"4142\" data-end=\"4155\" data-col-size=\"sm\"\u003e21 Liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4156\" data-end=\"4191\"\u003e\n\u003ctd data-start=\"4156\" data-end=\"4174\" data-col-size=\"sm\"\u003eNumber of Trays\u003c\/td\u003e\n\u003ctd data-start=\"4174\" data-end=\"4191\" data-col-size=\"sm\"\u003eUp to 5 trays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4192\" data-end=\"4238\"\u003e\n\u003ctd data-start=\"4192\" data-end=\"4215\" data-col-size=\"sm\"\u003eUnwrapped Cycle Time\u003c\/td\u003e\n\u003ctd data-start=\"4215\" data-end=\"4238\" data-col-size=\"sm\"\u003e38 minutes at 273°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4239\" data-end=\"4291\"\u003e\n\u003ctd data-start=\"4239\" data-end=\"4268\" data-col-size=\"sm\"\u003eDelicate Instruments Cycle\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4268\" data-end=\"4291\"\u003e46 minutes at 250°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4292\" data-end=\"4344\"\u003e\n\u003ctd data-start=\"4292\" data-end=\"4313\" data-col-size=\"sm\"\u003eOverall Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"4313\" data-end=\"4344\" data-col-size=\"sm\"\u003e17 1\/2 × 19 1\/2 × 23 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4345\" data-end=\"4373\"\u003e\n\u003ctd data-start=\"4345\" data-end=\"4365\" data-col-size=\"sm\"\u003ePower Requirement\u003c\/td\u003e\n\u003ctd data-start=\"4365\" data-end=\"4373\" data-col-size=\"sm\"\u003e110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4374\" data-end=\"4400\"\u003e\n\u003ctd data-start=\"4374\" data-end=\"4388\" data-col-size=\"sm\"\u003eUNSPSC Code\u003c\/td\u003e\n\u003ctd data-start=\"4388\" data-end=\"4400\" data-col-size=\"sm\"\u003e42281508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4401\" data-end=\"4442\"\u003e\n\u003ctd data-start=\"4401\" data-end=\"4436\" data-col-size=\"sm\"\u003eBuy American Act (BAA) Compliant\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4436\" data-end=\"4442\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4443\" data-end=\"4487\"\u003e\n\u003ctd data-start=\"4443\" data-end=\"4481\" data-col-size=\"sm\"\u003eTrade Agreement Act (TAA) Compliant\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4481\" data-end=\"4487\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4488\" data-end=\"4519\"\u003e\n\u003ctd data-start=\"4488\" data-end=\"4508\" data-col-size=\"sm\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-start=\"4508\" data-end=\"4519\" data-col-size=\"sm\"\u003eUnknown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 data-section-id=\"lvblon\" data-start=\"4526\" data-end=\"4566\"\u003eWho Should Use the T-Top 11B Autoclave\u003c\/h2\u003e\n\u003cp data-start=\"4568\" data-end=\"4701\"\u003eThe \u003cstrong data-start=\"4572\" data-end=\"4613\"\u003eTuttnauer T-Top 11B Class B Autoclave\u003c\/strong\u003e is designed for facilities that require advanced sterilization capabilities, including:\u003c\/p\u003e\n\u003cul data-start=\"4703\" data-end=\"4889\"\u003e\n\u003cli data-section-id=\"kehnbj\" data-start=\"4703\" data-end=\"4721\"\u003eDental clinics\u003c\/li\u003e\n\u003cli data-section-id=\"12pxdkl\" data-start=\"4722\" data-end=\"4762\"\u003eMedical clinics and surgical centers\u003c\/li\u003e\n\u003cli data-section-id=\"3o4pkt\" data-start=\"4763\" data-end=\"4787\"\u003eVeterinary practices\u003c\/li\u003e\n\u003cli data-section-id=\"1sfq8ju\" data-start=\"4788\" data-end=\"4815\"\u003eDiagnostic laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"roqxn3\" data-start=\"4816\" data-end=\"4846\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"g4xebj\" data-start=\"4847\" data-end=\"4889\"\u003eResearch institutions and universities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBecause the autoclave can sterilize \u003cstrong data-start=\"4927\" data-end=\"4964\"\u003ewrapped, hollow, and porous loads\u003c\/strong\u003e, it is ideal for environments that require \u003cstrong data-start=\"5008\" data-end=\"5065\"\u003estrict infection control and sterilization standards.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"qbiit0\" data-start=\"5072\" data-end=\"5107\"\u003eHow Class B Steam Autoclaves Work\u003c\/h2\u003e\n\u003cp data-start=\"5109\" data-end=\"5233\"\u003eClass B autoclaves use \u003cstrong data-start=\"5132\" data-end=\"5171\"\u003evacuum-assisted steam sterilization\u003c\/strong\u003e to ensure complete sterilization of complex instrument loads.\u003c\/p\u003e\n\u003cp data-start=\"5235\" data-end=\"5270\"\u003eThe sterilization process includes:\u003c\/p\u003e\n\u003col data-start=\"5272\" data-end=\"5617\"\u003e\n\u003cli data-section-id=\"1qfrdkt\" data-start=\"5272\" data-end=\"5390\"\u003e\n\u003cstrong data-start=\"5275\" data-end=\"5295\"\u003ePre-Vacuum Phase\u003c\/strong\u003e\u003cbr data-start=\"5295\" data-end=\"5298\"\u003eAir is removed from the chamber to allow steam to fully penetrate instruments and materials.\u003c\/li\u003e\n\u003cli data-section-id=\"16tstje\" data-start=\"5392\" data-end=\"5521\"\u003e\n\u003cstrong data-start=\"5395\" data-end=\"5424\"\u003eSteam Sterilization Phase\u003c\/strong\u003e\u003cbr data-start=\"5424\" data-end=\"5427\"\u003ePressurized steam reaches temperatures between \u003cstrong data-start=\"5474\" data-end=\"5493\"\u003e250°F and 273°F\u003c\/strong\u003e, destroying microorganisms.\u003c\/li\u003e\n\u003cli data-section-id=\"1mpzhjz\" data-start=\"5523\" data-end=\"5617\"\u003e\n\u003cstrong data-start=\"5526\" data-end=\"5554\"\u003ePost-Vacuum Drying Phase\u003c\/strong\u003e\u003cbr data-start=\"5554\" data-end=\"5557\"\u003eAir is removed again to dry instruments after sterilization.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"5619\" data-end=\"5770\"\u003eThis multi-stage sterilization process ensures \u003cstrong data-start=\"5666\" data-end=\"5720\"\u003edeep steam penetration and effective sterilization\u003c\/strong\u003e, even for hollow devices and wrapped instruments.\u003c\/p\u003e","brand":"T-Top","offers":[{"title":"Default Title","offer_id":44259865493597,"sku":"1267930","price":11833.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/tuttnauer-t-top-11b-benchtop-autoclave-21l-class-b-steam-sterilizer-1267930-1227011018.png?v=1773279789","url":"https:\/\/labequipmentdirect.com\/products\/tuttnauer-t-top-11b-benchtop-autoclave","provider":"Lab Equipment Direct","version":"1.0","type":"link"}