{"product_id":"tuttnauer-t-classic-9-benchtop-autoclave","title":"Tuttnauer T-Classic 9 Benchtop Autoclave – 9L Portable Steam Sterilizer","description":"\u003ch2\u003eCompact 9L Benchtop Steam Autoclave for Laboratories and Clinics\u003c\/h2\u003e\n\u003cp data-start=\"475\" data-end=\"714\"\u003eThe \u003cstrong data-start=\"479\" data-end=\"523\"\u003eTuttnauer T-Classic 9 Benchtop Autoclave\u003c\/strong\u003e is a compact and portable \u003cstrong data-start=\"550\" data-end=\"588\"\u003e9-liter steam sterilization system\u003c\/strong\u003e designed for laboratories, medical clinics, and research facilities that require reliable sterilization in a small footprint.\u003c\/p\u003e\n\u003cp data-start=\"716\" data-end=\"1119\"\u003eThis lightweight autoclave provides \u003cstrong data-start=\"752\" data-end=\"829\"\u003efully automatic sterilization cycles starting at just 18 minutes at 250°F\u003c\/strong\u003e, making it an efficient solution for sterilizing small laboratory instruments, tools, and equipment. With its \u003cstrong data-start=\"940\" data-end=\"998\"\u003esimple one-touch operation and portable 11.7-lb design\u003c\/strong\u003e, the T-Classic 9 is ideal for labs that need dependable sterilization without the complexity of large autoclave systems.\u003c\/p\u003e\n\u003ch2 data-section-id=\"18ahhlx\" data-start=\"1369\" data-end=\"1413\"\u003eWhat the T-Classic 9 Autoclave Is Used For\u003c\/h2\u003e\n\u003cp data-start=\"1415\" data-end=\"1652\"\u003eA \u003cstrong data-start=\"1417\" data-end=\"1439\"\u003ebenchtop autoclave\u003c\/strong\u003e is used to sterilize laboratory and medical instruments by exposing them to \u003cstrong data-start=\"1516\" data-end=\"1558\"\u003epressurized steam at high temperatures\u003c\/strong\u003e. This process eliminates harmful microorganisms such as bacteria, viruses, fungi, and spores.\u003c\/p\u003e\n\u003cp data-start=\"1654\" data-end=\"1717\"\u003eThe \u003cstrong data-start=\"1658\" data-end=\"1683\"\u003eT-Classic 9 autoclave\u003c\/strong\u003e is commonly used for sterilizing:\u003c\/p\u003e\n\u003cul data-start=\"1719\" data-end=\"1874\"\u003e\n\u003cli data-section-id=\"1qzgm05\" data-start=\"1719\" data-end=\"1749\"\u003eSmall surgical instruments\u003c\/li\u003e\n\u003cli data-section-id=\"mioim9\" data-start=\"1750\" data-end=\"1784\"\u003eLaboratory tools and equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1v88a2n\" data-start=\"1785\" data-end=\"1820\"\u003eGlassware and metal instruments\u003c\/li\u003e\n\u003cli data-section-id=\"1pr11pl\" data-start=\"1821\" data-end=\"1847\"\u003eDiagnostic instruments\u003c\/li\u003e\n\u003cli data-section-id=\"1uua7zo\" data-start=\"1848\" data-end=\"1874\"\u003eResearch lab equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"u0ybrq\" data-start=\"2068\" data-end=\"2082\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2084\" data-end=\"2267\"\u003e\n\u003cstrong data-start=\"2084\" data-end=\"2124\"\u003eFully Automatic One-Touch Operation:\u003c\/strong\u003e\u003cbr data-start=\"2124\" data-end=\"2127\"\u003eStart sterilization cycles quickly with a simple push-button control system designed to reduce user error and simplify laboratory workflows.\u003c\/li\u003e\n\u003cli data-start=\"2269\" data-end=\"2433\"\u003e\n\u003cstrong data-start=\"2269\" data-end=\"2308\"\u003eFast 18-Minute Sterilization Cycle:\u003c\/strong\u003e\u003cbr data-start=\"2308\" data-end=\"2311\"\u003eProvides rapid sterilization at \u003cstrong data-start=\"2343\" data-end=\"2370\"\u003e250°F steam temperature\u003c\/strong\u003e, allowing labs to process instruments quickly and efficiently.\u003c\/li\u003e\n\u003cli data-start=\"2435\" data-end=\"2612\"\u003e\n\u003cstrong data-start=\"2435\" data-end=\"2463\"\u003eCompact 9-Liter Chamber:\u003c\/strong\u003e\u003cbr data-start=\"2463\" data-end=\"2466\"\u003eThe \u003cstrong data-start=\"2470\" data-end=\"2496\"\u003e8-1\/5 × 9 inch chamber\u003c\/strong\u003e accommodates instruments up to \u003cstrong data-start=\"2528\" data-end=\"2545\"\u003e9 inches long\u003c\/strong\u003e, making it ideal for small laboratory tools and medical equipment.\u003c\/li\u003e\n\u003cli data-start=\"2614\" data-end=\"2764\"\u003e\n\u003cstrong data-start=\"2614\" data-end=\"2646\"\u003eLightweight Portable Design:\u003c\/strong\u003e\u003cbr data-start=\"2646\" data-end=\"2649\"\u003eWeighing only \u003cstrong data-start=\"2663\" data-end=\"2678\"\u003e11.7 pounds\u003c\/strong\u003e, this autoclave is easy to move between workstations or transport to field locations.\u003c\/li\u003e\n\u003cli data-start=\"2766\" data-end=\"2935\"\u003e\n\u003cstrong data-start=\"2766\" data-end=\"2810\"\u003eReliable Steam Sterilization Technology:\u003c\/strong\u003e\u003cbr data-start=\"2810\" data-end=\"2813\"\u003eUses \u003cstrong data-start=\"2818\" data-end=\"2856\"\u003ehigh-temperature pressurized steam\u003c\/strong\u003e, one of the most trusted sterilization methods for eliminating microorganisms.\u003c\/li\u003e\n\u003cli data-start=\"2937\" data-end=\"3089\"\u003e\n\u003cstrong data-start=\"2937\" data-end=\"2975\"\u003eStandard Electrical Compatibility:\u003c\/strong\u003e\u003cbr data-start=\"2975\" data-end=\"2978\"\u003eOperates on \u003cstrong data-start=\"2990\" data-end=\"3013\"\u003e120V, 50\/60Hz power\u003c\/strong\u003e, allowing it to plug into standard electrical outlets in most laboratories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"zjxypn\" data-start=\"3096\" data-end=\"3122\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3124\" data-end=\"3835\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3124\" data-end=\"3151\"\u003e\n\u003ctr data-start=\"3124\" data-end=\"3151\"\u003e\n\u003cth data-start=\"3124\" data-end=\"3140\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3140\" data-end=\"3151\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3162\" data-end=\"3835\"\u003e\n\u003ctr data-start=\"3162\" data-end=\"3211\"\u003e\n\u003ctd data-start=\"3162\" data-end=\"3177\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3177\" data-end=\"3211\"\u003eT-Classic 9 Benchtop Autoclave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3212\" data-end=\"3244\"\u003e\n\u003ctd data-start=\"3212\" data-end=\"3227\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3227\" data-end=\"3244\"\u003eTuttnauer USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3245\" data-end=\"3287\"\u003e\n\u003ctd data-start=\"3245\" data-end=\"3272\" data-col-size=\"sm\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3272\" data-end=\"3287\"\u003eT-CLASSIC 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3288\" data-end=\"3317\"\u003e\n\u003ctd data-start=\"3288\" data-end=\"3306\" data-col-size=\"sm\"\u003eMcKesson Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3306\" data-end=\"3317\"\u003e1222893\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3318\" data-end=\"3354\"\u003e\n\u003ctd data-start=\"3318\" data-end=\"3332\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3332\" data-end=\"3354\"\u003eBenchtop Autoclave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3355\" data-end=\"3387\"\u003e\n\u003ctd data-start=\"3355\" data-end=\"3378\" data-col-size=\"sm\"\u003eSterilization Method\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3378\" data-end=\"3387\"\u003eSteam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3388\" data-end=\"3429\"\u003e\n\u003ctd data-start=\"3388\" data-end=\"3409\" data-col-size=\"sm\"\u003eChamber Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3409\" data-end=\"3429\"\u003e8-1\/5 × 9 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3430\" data-end=\"3475\"\u003e\n\u003ctd data-start=\"3430\" data-end=\"3449\" data-col-size=\"sm\"\u003eChamber Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3449\" data-end=\"3475\"\u003e9 liters (2.4 gallons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3476\" data-end=\"3516\"\u003e\n\u003ctd data-start=\"3476\" data-end=\"3504\" data-col-size=\"sm\"\u003eMaximum Instrument Length\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3504\" data-end=\"3516\"\u003e9 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3517\" data-end=\"3554\"\u003e\n\u003ctd data-start=\"3517\" data-end=\"3540\" data-col-size=\"sm\"\u003eUnwrapped Cycle Time\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3540\" data-end=\"3554\"\u003e18 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3555\" data-end=\"3592\"\u003e\n\u003ctd data-start=\"3555\" data-end=\"3583\" data-col-size=\"sm\"\u003eSterilization Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3583\" data-end=\"3592\"\u003e250°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3593\" data-end=\"3631\"\u003e\n\u003ctd data-start=\"3593\" data-end=\"3614\" data-col-size=\"sm\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3614\" data-end=\"3631\"\u003e120V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3632\" data-end=\"3658\"\u003e\n\u003ctd data-start=\"3632\" data-end=\"3646\" data-col-size=\"sm\"\u003eUnit Weight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3646\" data-end=\"3658\"\u003e11.7 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3659\" data-end=\"3689\"\u003e\n\u003ctd data-start=\"3659\" data-end=\"3676\" data-col-size=\"sm\"\u003eOverall Height\u003c\/td\u003e\n\u003ctd data-start=\"3676\" data-end=\"3689\" data-col-size=\"sm\"\u003e13 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3690\" data-end=\"3721\"\u003e\n\u003ctd data-start=\"3690\" data-end=\"3710\" data-col-size=\"sm\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3710\" data-end=\"3721\"\u003eUnknown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3722\" data-end=\"3748\"\u003e\n\u003ctd data-start=\"3722\" data-end=\"3736\" data-col-size=\"sm\"\u003eUNSPSC Code\u003c\/td\u003e\n\u003ctd data-start=\"3736\" data-end=\"3748\" data-col-size=\"sm\"\u003e42281508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3749\" data-end=\"3790\"\u003e\n\u003ctd data-start=\"3749\" data-end=\"3784\" data-col-size=\"sm\"\u003eBuy American Act (BAA) Compliant\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3784\" data-end=\"3790\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3791\" data-end=\"3835\"\u003e\n\u003ctd data-start=\"3791\" data-end=\"3829\" data-col-size=\"sm\"\u003eTrade Agreement Act (TAA) Compliant\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3829\" data-end=\"3835\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 data-section-id=\"1f1w48j\" data-start=\"3842\" data-end=\"3884\"\u003eWho Should Use the T-Classic 9 Autoclave\u003c\/h2\u003e\n\u003cp data-start=\"3886\" data-end=\"4035\"\u003eThe \u003cstrong data-start=\"3890\" data-end=\"3934\"\u003eTuttnauer T-Classic 9 Portable Autoclave\u003c\/strong\u003e is designed for professionals who require reliable sterilization in compact environments, including:\u003c\/p\u003e\n\u003cul data-start=\"4037\" data-end=\"4236\"\u003e\n\u003cli data-section-id=\"1tn30bp\" data-start=\"4037\" data-end=\"4073\"\u003eClinical diagnostic laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1hirw7o\" data-start=\"4074\" data-end=\"4099\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1ru5k8s\" data-start=\"4100\" data-end=\"4126\"\u003eBiotechnology startups\u003c\/li\u003e\n\u003cli data-section-id=\"g5fl0k\" data-start=\"4127\" data-end=\"4149\"\u003eVeterinary clinics\u003c\/li\u003e\n\u003cli data-section-id=\"43y7az\" data-start=\"4150\" data-end=\"4173\"\u003eDental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"xza0xq\" data-start=\"4174\" data-end=\"4206\"\u003eUniversity and academic labs\u003c\/li\u003e\n\u003cli data-section-id=\"1kqc1ts\" data-start=\"4207\" data-end=\"4236\"\u003eMobile medical facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts \u003cstrong data-start=\"4242\" data-end=\"4284\"\u003esmall footprint and lightweight design\u003c\/strong\u003e make it particularly useful for environments where space is limited but sterilization reliability is essential.\u003c\/p\u003e\n\u003ch2 data-section-id=\"nng594\" data-start=\"4403\" data-end=\"4430\"\u003eHow Steam Autoclaves Work\u003c\/h2\u003e\n\u003cp data-start=\"4432\" data-end=\"4707\"\u003eSteam autoclaves sterilize instruments by exposing them to \u003cstrong data-start=\"4491\" data-end=\"4569\"\u003epressurized saturated steam at temperatures typically around 250°F (121°C)\u003c\/strong\u003e. The combination of heat and pressure penetrates materials and destroys microorganisms by breaking down proteins and cellular structures.\u003c\/p\u003e\n\u003cp data-start=\"4709\" data-end=\"4798\"\u003eSteam sterilization is widely used in laboratories and healthcare settings because it is:\u003c\/p\u003e\n\u003cul data-start=\"4800\" data-end=\"5008\"\u003e\n\u003cli data-section-id=\"1g8hqa9\" data-start=\"4800\" data-end=\"4854\"\u003eHighly effective against microorganisms and spores\u003c\/li\u003e\n\u003cli data-section-id=\"balw86\" data-start=\"4855\" data-end=\"4882\"\u003eReliable and repeatable\u003c\/li\u003e\n\u003cli data-section-id=\"1rnx385\" data-start=\"4883\" data-end=\"4900\"\u003eChemical-free\u003c\/li\u003e\n\u003cli data-section-id=\"ia4r90\" data-start=\"4901\" data-end=\"4941\"\u003eSafe for metal and glass instruments\u003c\/li\u003e\n\u003cli data-section-id=\"zxau2x\" data-start=\"4942\" data-end=\"5008\"\u003eApproved for medical and laboratory sterilization applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"T-Classic","offers":[{"title":"Default Title","offer_id":44259369320541,"sku":"1222893","price":2022.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/tuttnauer-t-classic-9-benchtop-autoclave-9l-portable-steam-sterilizer-1222893-1226997769.png?v=1773272590","url":"https:\/\/labequipmentdirect.com\/products\/tuttnauer-t-classic-9-benchtop-autoclave","provider":"Lab Equipment Direct","version":"1.0","type":"link"}