{"product_id":"thermo-scientific-revco®-undercounter-laboratory-freezer-5-cu-ft-solid-door","title":"Thermo Scientific Revco® Undercounter Laboratory Freezer – 5 cu. ft., Solid Door","description":"\u003cp data-start=\"433\" data-end=\"815\"\u003eThe \u003cstrong data-start=\"437\" data-end=\"487\"\u003eRevco® ULT430A Undercounter Laboratory Freezer\u003c\/strong\u003e from Thermo Scientific delivers dependable, uniform low-temperature storage in a compact 5 cu. ft. design. Ideal for laboratories with limited space, this automatic-defrost freezer maintains temperatures between \u003cstrong data-start=\"700\" data-end=\"719\"\u003e–30°C and –15°C\u003c\/strong\u003e, making it suitable for enzymes, reagents, samples, controls, and general laboratory materials.\u003c\/p\u003e\n\u003cp data-start=\"817\" data-end=\"1280\"\u003eIntuitive \u003cstrong data-start=\"827\" data-end=\"850\"\u003eicon-based controls\u003c\/strong\u003e, a \u003cstrong data-start=\"854\" data-end=\"891\"\u003elarge digital temperature display\u003c\/strong\u003e, and a \u003cstrong data-start=\"899\" data-end=\"932\"\u003egraphic thermometer indicator\u003c\/strong\u003e ensure quick, accurate monitoring at a glance. Forced-air circulation enhances temperature uniformity and supports rapid temperature recovery after door openings, protecting sample integrity. The \u003cstrong data-start=\"1129\" data-end=\"1157\"\u003eon-demand defrost system\u003c\/strong\u003e minimizes frost buildup and eliminates the need for a defrost timer, ensuring optimal coil efficiency and low maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"1287\" data-end=\"1308\"\u003e✅ Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1313\" data-end=\"1331\"\u003e–30°C to –15°C\u003c\/strong\u003e laboratory-grade temperature range\u003cbr data-start=\"1366\" data-end=\"1369\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1372\" data-end=\"1393\"\u003eAutomatic defrost\u003c\/strong\u003e with condensate removal\u003cbr data-start=\"1417\" data-end=\"1420\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1423\" data-end=\"1446\"\u003eIcon-based controls\u003c\/strong\u003e for simple, intuitive operation\u003cbr data-start=\"1478\" data-end=\"1481\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1484\" data-end=\"1509\"\u003eLarge digital display\u003c\/strong\u003e shows temperature to within 1°C\u003cbr data-start=\"1541\" data-end=\"1544\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1547\" data-end=\"1580\"\u003eGraphic thermometer indicator\u003c\/strong\u003e for quick visual status checks\u003cbr data-start=\"1611\" data-end=\"1614\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1617\" data-end=\"1662\"\u003eOn-demand sensor-activated defrost system\u003c\/strong\u003e\u003cbr data-start=\"1662\" data-end=\"1665\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1668\" data-end=\"1694\"\u003eForced-air circulation\u003c\/strong\u003e for uniform temperatures and fast recovery\u003cbr data-start=\"1737\" data-end=\"1740\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1743\" data-end=\"1765\"\u003e5 cu. ft. capacity\u003c\/strong\u003e in a compact undercounter design\u003cbr data-start=\"1798\" data-end=\"1801\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ \u003cstrong data-start=\"1804\" data-end=\"1821\"\u003eThree shelves\u003c\/strong\u003e for organized storage\u003cbr data-start=\"1843\" data-end=\"1846\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1888\"\u003e✔️ Manufactured in the \u003cstrong data-start=\"1869\" data-end=\"1886\"\u003eUnited States\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1895\" data-end=\"1929\"\u003e📊 Technical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1931\" data-end=\"2478\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1931\" data-end=\"1966\"\u003e\n\u003ctr data-start=\"1931\" data-end=\"1966\"\u003e\n\u003cth data-start=\"1931\" data-end=\"1951\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1933\" data-end=\"1950\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1951\" data-end=\"1966\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1953\" data-end=\"1964\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2004\" data-end=\"2478\"\u003e\n\u003ctr data-start=\"2004\" data-end=\"2026\"\u003e\n\u003ctd data-start=\"2004\" data-end=\"2016\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2006\" data-end=\"2015\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2016\" data-end=\"2026\" data-col-size=\"sm\"\u003eRevco®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2027\" data-end=\"2067\"\u003e\n\u003ctd data-start=\"2027\" data-end=\"2046\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2029\" data-end=\"2045\"\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2046\" data-end=\"2067\" data-col-size=\"sm\"\u003eThermo Scientific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2068\" data-end=\"2100\"\u003e\n\u003ctd data-start=\"2068\" data-end=\"2089\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2070\" data-end=\"2088\"\u003eManufacturer #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2089\" data-end=\"2100\" data-col-size=\"sm\"\u003eULT430A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2101\" data-end=\"2143\"\u003e\n\u003ctd data-start=\"2101\" data-end=\"2119\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2103\" data-end=\"2118\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2119\" data-end=\"2143\" data-col-size=\"sm\"\u003eUndercounter Freezer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2144\" data-end=\"2173\"\u003e\n\u003ctd data-start=\"2144\" data-end=\"2155\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2146\" data-end=\"2154\"\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2155\" data-end=\"2173\" data-col-size=\"sm\"\u003eLaboratory Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2174\" data-end=\"2202\"\u003e\n\u003ctd data-start=\"2174\" data-end=\"2189\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2176\" data-end=\"2188\"\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2189\" data-end=\"2202\" data-col-size=\"sm\"\u003e5 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2203\" data-end=\"2244\"\u003e\n\u003ctd data-start=\"2203\" data-end=\"2227\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2205\" data-end=\"2226\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2227\" data-end=\"2244\" data-col-size=\"sm\"\u003e–30° to –15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2245\" data-end=\"2285\"\u003e\n\u003ctd data-start=\"2245\" data-end=\"2264\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2247\" data-end=\"2263\"\u003eDefrost Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2264\" data-end=\"2285\" data-col-size=\"sm\"\u003eAutomatic Defrost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2286\" data-end=\"2324\"\u003e\n\u003ctd data-start=\"2286\" data-end=\"2302\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2288\" data-end=\"2301\"\u003eDoor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2302\" data-end=\"2324\" data-col-size=\"sm\"\u003e1 Solid Swing Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2325\" data-end=\"2353\"\u003e\n\u003ctd data-start=\"2325\" data-end=\"2340\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2327\" data-end=\"2339\"\u003eShelving\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2340\" data-end=\"2353\" data-col-size=\"sm\"\u003e3 Shelves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2354\" data-end=\"2405\"\u003e\n\u003ctd data-start=\"2354\" data-end=\"2383\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2356\" data-end=\"2382\"\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2383\" data-end=\"2405\" data-col-size=\"sm\"\u003e24 × 28.9 × 34 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2406\" data-end=\"2447\"\u003e\n\u003ctd data-start=\"2406\" data-end=\"2430\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2429\"\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2430\" data-end=\"2447\" data-col-size=\"sm\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2448\" data-end=\"2478\"\u003e\n\u003ctd data-start=\"2448\" data-end=\"2466\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2450\" data-end=\"2465\"\u003eUNSPSC Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2466\" data-end=\"2478\" data-col-size=\"sm\"\u003e24131609\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"817\" data-end=\"1280\"\u003e \u003c\/p\u003e\n\u003ch2 data-start=\"3549\" data-end=\"3572\"\u003e⚠️ Safety Notice\u003c\/h2\u003e\n\u003cp data-start=\"3574\" data-end=\"4024\"\u003eInstall the freezer on a level, ventilated surface. Keep the solid swing door fully closed to maintain the –30°C to –15°C temperature range. Avoid overloading shelves to preserve airflow. Allow adequate clearance for ventilation and heat dissipation. The automatic defrost system activates as needed—do not attempt manual defrosting. Disconnect power before cleaning or servicing. Follow Thermo Scientific guidelines for storing laboratory materials.\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":43859184877661,"sku":"ULT430A","price":12215.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/thermo-scientific-revco-undercounter-laboratory-freezer-5-cu-ft-solid-door-ult430a-1209728863.jpg?v=1764719521","url":"https:\/\/labequipmentdirect.com\/products\/thermo-scientific-revco%c2%ae-undercounter-laboratory-freezer-5-cu-ft-solid-door","provider":"Lab Equipment Direct","version":"1.0","type":"link"}