{"product_id":"thermo-scientific™-tsx-universal-series-ultra-low-freezer-28-8-cu-ft-3","title":"Thermo Scientific™ TSX Universal Series Ultra-Low Freezer – 28.8 cu.ft.","description":"\u003cp data-start=\"341\" data-end=\"659\"\u003eThe \u003cstrong data-start=\"345\" data-end=\"420\"\u003eThermo Scientific™ TSX Universal Series Ultra-Low Freezer (28.8 cu.ft.)\u003c\/strong\u003e is engineered to deliver exceptional protection for high-value biological samples. With a temperature range of \u003cstrong data-start=\"532\" data-end=\"549\"\u003e–40° to –86°C\u003c\/strong\u003e, this ULT freezer ensures reliable long-term storage for research, clinical, and pharmaceutical applications.\u003c\/p\u003e\n\u003cp data-start=\"661\" data-end=\"1012\"\u003eThis model features \u003cstrong data-start=\"681\" data-end=\"701\"\u003e600-box capacity\u003c\/strong\u003e, \u003cstrong data-start=\"703\" data-end=\"727\"\u003esliding drawer racks\u003c\/strong\u003e, and a \u003cstrong data-start=\"735\" data-end=\"774\"\u003efactory-installed LN₂ backup system\u003c\/strong\u003e for maximum security during power outages or compressor interruptions. Built with energy-efficient insulation and a rugged steel exterior, the TSX60086FARAKLN is a premium solution for laboratories that demand uncompromising performance.\u003c\/p\u003e\n\u003ch2 data-start=\"1019\" data-end=\"1040\"\u003e✅ Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ Ultra-low temperature storage: \u003cstrong data-start=\"1076\" data-end=\"1093\"\u003e–40° to –86°C\u003c\/strong\u003e\u003cbr data-start=\"1093\" data-end=\"1096\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ \u003cstrong data-start=\"1099\" data-end=\"1127\"\u003e600-box storage capacity\u003c\/strong\u003e\u003cbr data-start=\"1127\" data-end=\"1130\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ Includes \u003cstrong data-start=\"1142\" data-end=\"1181\"\u003etwo shelves of sliding drawer racks\u003c\/strong\u003e designed for 2-inch boxes\u003cbr data-start=\"1207\" data-end=\"1210\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ \u003cstrong data-start=\"1213\" data-end=\"1270\"\u003eFactory-installed liquid nitrogen (LN₂) backup system\u003c\/strong\u003e\u003cbr data-start=\"1270\" data-end=\"1273\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ Rugged painted steel construction for long-term durability\u003cbr data-start=\"1334\" data-end=\"1337\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ Manual defrost ensures stable, uniform temperatures\u003cbr data-start=\"1391\" data-end=\"1394\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ Four inner doors minimize thermal loss during access\u003cbr data-start=\"1449\" data-end=\"1452\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ Precision temperature performance ideal for critical samples\u003cbr data-start=\"1515\" data-end=\"1518\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1583\"\u003e✔️ Designed for high-demand research and general laboratory use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1590\" data-end=\"1624\"\u003e📊 Technical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1626\" data-end=\"2318\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1626\" data-end=\"1661\"\u003e\n\u003ctr data-start=\"1626\" data-end=\"1661\"\u003e\n\u003cth data-start=\"1626\" data-end=\"1646\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1628\" data-end=\"1645\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1646\" data-end=\"1661\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1648\" data-end=\"1659\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1699\" data-end=\"2318\"\u003e\n\u003ctr data-start=\"1699\" data-end=\"1754\"\u003e\n\u003ctd data-start=\"1699\" data-end=\"1711\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1701\" data-end=\"1710\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1711\" data-end=\"1754\" data-col-size=\"sm\"\u003eThermo Scientific™ TSX Universal Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1755\" data-end=\"1794\"\u003e\n\u003ctd data-start=\"1755\" data-end=\"1775\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1757\" data-end=\"1774\"\u003eModel \/ Mfg #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1775\" data-end=\"1794\" data-col-size=\"sm\"\u003eTSX60086FARAKLN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1795\" data-end=\"1823\"\u003e\n\u003ctd data-start=\"1795\" data-end=\"1812\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1797\" data-end=\"1811\"\u003eMcKesson #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1812\" data-end=\"1823\" data-col-size=\"sm\"\u003e1254990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1824\" data-end=\"1856\"\u003e\n\u003ctd data-start=\"1824\" data-end=\"1835\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1826\" data-end=\"1834\"\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1835\" data-end=\"1856\" data-col-size=\"sm\"\u003eUltra-Low Freezer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1857\" data-end=\"1887\"\u003e\n\u003ctd data-start=\"1857\" data-end=\"1872\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1859\" data-end=\"1871\"\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1872\" data-end=\"1887\" data-col-size=\"sm\"\u003e28.8 cu.ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1888\" data-end=\"1929\"\u003e\n\u003ctd data-start=\"1888\" data-end=\"1912\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1890\" data-end=\"1911\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1912\" data-end=\"1929\" data-col-size=\"sm\"\u003e–40° to –86°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1930\" data-end=\"1967\"\u003e\n\u003ctd data-start=\"1930\" data-end=\"1949\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1932\" data-end=\"1948\"\u003eDefrost Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1949\" data-end=\"1967\" data-col-size=\"sm\"\u003eManual Defrost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1968\" data-end=\"2016\"\u003e\n\u003ctd data-start=\"1968\" data-end=\"1984\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1970\" data-end=\"1983\"\u003eDoor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1984\" data-end=\"2016\" data-col-size=\"sm\"\u003e1 Outer Door \/ 2 Inner Doors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2017\" data-end=\"2044\"\u003e\n\u003ctd data-start=\"2017\" data-end=\"2031\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2019\" data-end=\"2030\"\u003eShelves\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2031\" data-end=\"2044\" data-col-size=\"sm\"\u003e4 Shelves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2045\" data-end=\"2091\"\u003e\n\u003ctd data-start=\"2045\" data-end=\"2062\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2047\" data-end=\"2061\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2062\" data-end=\"2091\" data-col-size=\"sm\"\u003e37.6\" W × 39.6\" D × 78\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2092\" data-end=\"2144\"\u003e\n\u003ctd data-start=\"2092\" data-end=\"2112\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2094\" data-end=\"2111\"\u003eBackup System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2112\" data-end=\"2144\" data-col-size=\"sm\"\u003eFactory-installed LN₂ backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2145\" data-end=\"2207\"\u003e\n\u003ctd data-start=\"2145\" data-end=\"2166\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2147\" data-end=\"2165\"\u003eStorage Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2166\" data-end=\"2207\" data-col-size=\"sm\"\u003eSliding drawer racks for 2-inch boxes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2208\" data-end=\"2245\"\u003e\n\u003ctd data-start=\"2208\" data-end=\"2226\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2210\" data-end=\"2225\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2226\" data-end=\"2245\" data-col-size=\"sm\"\u003eGeneral Purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2246\" data-end=\"2276\"\u003e\n\u003ctd data-start=\"2246\" data-end=\"2264\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2248\" data-end=\"2263\"\u003eUNSPSC Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2264\" data-end=\"2276\" data-col-size=\"sm\"\u003e41103011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2277\" data-end=\"2318\"\u003e\n\u003ctd data-start=\"2277\" data-end=\"2301\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2279\" data-end=\"2300\"\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2301\" data-end=\"2318\" data-col-size=\"sm\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"661\" data-end=\"1012\"\u003e \u003c\/p\u003e\n\u003ch2 data-start=\"2593\" data-end=\"2616\"\u003e⚠️ \u003cstrong data-start=\"2599\" data-end=\"2616\"\u003eSafety Notice\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"2618\" data-end=\"3194\"\u003eInstall the freezer on a level, well-ventilated surface with proper clearance for airflow and service access. Ensure that personnel operating the LN₂ backup system are trained in cryogenic safety procedures. Avoid unnecessary door openings to maintain temperature stability. Connect the freezer to a dedicated, grounded electrical outlet and use backup power where required. Regularly inspect alarms, monitor temperature logs, and follow Thermo Scientific’s recommended maintenance guidelines. Disconnect the unit from power before performing cleaning or servicing operations.\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":43866999947357,"sku":"TSX60086FARAKLN","price":45114.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/thermo-scientific-tsx-universal-series-ultra-low-freezer-28-8-cu-ft-tsx60086farakln-1210081781.jpg?v=1764899883","url":"https:\/\/labequipmentdirect.com\/products\/thermo-scientific%e2%84%a2-tsx-universal-series-ultra-low-freezer-28-8-cu-ft-3","provider":"Lab Equipment Direct","version":"1.0","type":"link"}