{"product_id":"thermo-scientific™-tsx-universal-series-ultra-low-freezer-19-4-cu-ft","title":"Thermo Scientific™ TSX Universal Series Ultra-Low Freezer – 19.4 cu. ft.","description":"\u003cp data-start=\"509\" data-end=\"950\"\u003eThe \u003cstrong data-start=\"513\" data-end=\"570\"\u003eThermo Scientific™ TSX40086FA2IDREP Ultra-Low Freezer\u003c\/strong\u003e delivers exceptional performance, durability, and energy efficiency for laboratories requiring secure long-term storage of high-value biological materials. With a \u003cstrong data-start=\"734\" data-end=\"750\"\u003e19.4 cu. ft.\u003c\/strong\u003e capacity and a stable temperature range of \u003cstrong data-start=\"794\" data-end=\"812\"\u003e–40°C to –86°C\u003c\/strong\u003e, this freezer combines advanced V-Drive technology, robust construction, and precision temperature control to safeguard critical samples.\u003c\/p\u003e\n\u003cp data-start=\"952\" data-end=\"1335\"\u003eBuilt in ISO 13485:2016 facilities, each unit undergoes \u003cstrong data-start=\"1008\" data-end=\"1050\"\u003eover 10,000 hours of intensive testing\u003c\/strong\u003e and strict end-of-line quality verification. The universal V-Drive technology intelligently adapts compressor speed to user activity, ensuring peak efficiency and consistent temperature recovery after door openings—while maintaining \u003cstrong data-start=\"1284\" data-end=\"1334\"\u003eless than 4°C variation throughout the cabinet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1337\" data-end=\"1673\"\u003eA compact footprint, universal voltage, ergonomic handle, and whisper-quiet operation make this unit ideal for research, clinical laboratories, biobanks, and pharmaceutical facilities. Advanced insulation, ENERGY STAR® certification, and rapid cooldown time (reaching –80°C in under 5 hours) further enhance reliability and performance.\u003c\/p\u003e\n\u003ch2 data-start=\"1680\" data-end=\"1701\"\u003e✅\u003cstrong\u003e \u003c\/strong\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"1706\" data-end=\"1738\"\u003eUltra-low temperature range:\u003c\/strong\u003e –40°C to –86°C\u003cbr data-start=\"1753\" data-end=\"1756\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"1759\" data-end=\"1784\"\u003e19.4 cu. ft. capacity\u003c\/strong\u003e with adjustable shelving\u003cbr data-start=\"1809\" data-end=\"1812\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"1815\" data-end=\"1847\"\u003eUniversal V-Drive technology\u003c\/strong\u003e for energy savings and rapid recovery\u003cbr data-start=\"1885\" data-end=\"1888\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"1891\" data-end=\"1933\"\u003e10,000+ hours of lab and field testing\u003c\/strong\u003e for proven durability\u003cbr data-start=\"1955\" data-end=\"1958\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"1961\" data-end=\"2003\"\u003eISO 13485:2016–certified manufacturing\u003c\/strong\u003e ensures consistent quality\u003cbr data-start=\"2030\" data-end=\"2033\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ Achieves \u003cstrong data-start=\"2045\" data-end=\"2071\"\u003e–80°C in under 5 hours\u003c\/strong\u003e, 41% faster than previous models\u003cbr data-start=\"2104\" data-end=\"2107\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"2110\" data-end=\"2133\"\u003eStable temperatures\u003c\/strong\u003e with \u0026lt;4°C variation throughout the cabinet\u003cbr data-start=\"2176\" data-end=\"2179\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"2182\" data-end=\"2208\"\u003eENERGY STAR® certified\u003c\/strong\u003e for reduced energy consumption\u003cbr data-start=\"2239\" data-end=\"2242\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"2245\" data-end=\"2300\"\u003eAdvanced vacuum insulation + 0 GWP water-blown foam\u003c\/strong\u003e\u003cbr data-start=\"2300\" data-end=\"2303\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"2306\" data-end=\"2326\"\u003eErgonomic handle\u003c\/strong\u003e ensures tight sealing and temperature protection\u003cbr data-start=\"2375\" data-end=\"2378\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ \u003cstrong data-start=\"2381\" data-end=\"2421\"\u003e7-point gasket with perimeter heater\u003c\/strong\u003e to reduce frost buildup\u003cbr data-start=\"2445\" data-end=\"2448\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ Whisper-quiet performance suitable for in-room laboratory use\u003cbr data-start=\"2512\" data-end=\"2515\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1703\" data-end=\"2577\"\u003e✔️ Universal voltage compatibility for flexible installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2584\" data-end=\"2618\"\u003e📊 Technical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2620\" data-end=\"3337\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2620\" data-end=\"2655\"\u003e\n\u003ctr data-start=\"2620\" data-end=\"2655\"\u003e\n\u003cth data-start=\"2620\" data-end=\"2640\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2622\" data-end=\"2639\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2640\" data-end=\"2655\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2642\" data-end=\"2653\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2693\" data-end=\"3337\"\u003e\n\u003ctr data-start=\"2693\" data-end=\"2748\"\u003e\n\u003ctd data-start=\"2693\" data-end=\"2705\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2695\" data-end=\"2704\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2705\" data-end=\"2748\" data-col-size=\"sm\"\u003eThermo Scientific™ TSX Universal Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2749\" data-end=\"2789\"\u003e\n\u003ctd data-start=\"2749\" data-end=\"2768\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2751\" data-end=\"2767\"\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2768\" data-end=\"2789\" data-col-size=\"sm\"\u003eThermo Scientific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2790\" data-end=\"2831\"\u003e\n\u003ctd data-start=\"2790\" data-end=\"2811\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2792\" data-end=\"2810\"\u003eManufacturer #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2811\" data-end=\"2831\" data-col-size=\"sm\"\u003eTSX40086FA2IDREP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2832\" data-end=\"2871\"\u003e\n\u003ctd data-start=\"2832\" data-end=\"2850\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2834\" data-end=\"2849\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2850\" data-end=\"2871\" data-col-size=\"sm\"\u003eUltra-Low Freezer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2872\" data-end=\"2901\"\u003e\n\u003ctd data-start=\"2872\" data-end=\"2883\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2874\" data-end=\"2882\"\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2883\" data-end=\"2901\"\u003eLaboratory Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2902\" data-end=\"2933\"\u003e\n\u003ctd data-start=\"2902\" data-end=\"2917\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2904\" data-end=\"2916\"\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2917\" data-end=\"2933\" data-col-size=\"sm\"\u003e19.4 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2934\" data-end=\"2976\"\u003e\n\u003ctd data-start=\"2934\" data-end=\"2958\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2936\" data-end=\"2957\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2958\" data-end=\"2976\" data-col-size=\"sm\"\u003e–40°C to –86°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2977\" data-end=\"3014\"\u003e\n\u003ctd data-start=\"2977\" data-end=\"2996\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2979\" data-end=\"2995\"\u003eDefrost Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2996\" data-end=\"3014\"\u003eManual Defrost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3015\" data-end=\"3047\"\u003e\n\u003ctd data-start=\"3015\" data-end=\"3031\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3017\" data-end=\"3030\"\u003eDoor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3031\" data-end=\"3047\"\u003e1 Solid Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3048\" data-end=\"3075\"\u003e\n\u003ctd data-start=\"3048\" data-end=\"3062\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3050\" data-end=\"3061\"\u003eShelves\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3062\" data-end=\"3075\" data-col-size=\"sm\"\u003e3 Shelves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3076\" data-end=\"3129\"\u003e\n\u003ctd data-start=\"3076\" data-end=\"3105\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3078\" data-end=\"3104\"\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3105\" data-end=\"3129\"\u003e28.3 × 37.6 × 78 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3130\" data-end=\"3177\"\u003e\n\u003ctd data-start=\"3130\" data-end=\"3159\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3132\" data-end=\"3158\"\u003eManufacturing Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3159\" data-end=\"3177\" data-col-size=\"sm\"\u003eISO 13485:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3178\" data-end=\"3224\"\u003e\n\u003ctd data-start=\"3178\" data-end=\"3198\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3180\" data-end=\"3197\"\u003eEnergy Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3198\" data-end=\"3224\"\u003eENERGY STAR® Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3225\" data-end=\"3270\"\u003e\n\u003ctd data-start=\"3225\" data-end=\"3243\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3227\" data-end=\"3242\"\u003eNoise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3243\" data-end=\"3270\"\u003eWhisper-quiet operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3271\" data-end=\"3306\"\u003e\n\u003ctd data-start=\"3271\" data-end=\"3295\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3273\" data-end=\"3294\"\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3295\" data-end=\"3306\"\u003eUnknown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3307\" data-end=\"3337\"\u003e\n\u003ctd data-start=\"3307\" data-end=\"3325\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3309\" data-end=\"3324\"\u003eUNSPSC Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3325\" data-end=\"3337\" data-col-size=\"sm\"\u003e41103011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"1337\" data-end=\"1673\"\u003e \u003c\/p\u003e\n\u003ch2 data-start=\"4507\" data-end=\"4530\"\u003e⚠️ \u003cstrong data-start=\"4513\" data-end=\"4530\"\u003eSafety Notice\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"4532\" data-end=\"5046\"\u003eInstall the freezer on a stable, ventilated surface and ensure clearance for airflow. To maintain optimal performance, keep the solid door sealed tightly using the ergonomic handle and avoid prolonged door openings. Because the unit operates on \u003cstrong data-start=\"4777\" data-end=\"4795\"\u003emanual defrost\u003c\/strong\u003e, monitor frost accumulation and schedule defrosting to maintain temperature accuracy. Verify alarms regularly and follow all manufacturer recommendations for sample protection and equipment maintenance. Disconnect power before performing any service.\u003c\/p\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":43862551396445,"sku":"1277212","price":22893.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/thermo-scientific-tsx-universal-series-ultra-low-freezer-19-4-cu-ft-tsx40086fa2idrep-1209851286.png?v=1764798728","url":"https:\/\/labequipmentdirect.com\/products\/thermo-scientific%e2%84%a2-tsx-universal-series-ultra-low-freezer-19-4-cu-ft","provider":"Lab Equipment Direct","version":"1.0","type":"link"}