{"product_id":"thermo-forma-series-ii-co2-incubator-6-5-cu-ft","title":"Thermo Scientific Forma Series II CO₂ Incubator – 6.5 cu. ft. Water Jacket (Model 3120)","description":"\u003ch2 data-section-id=\"vpl95h\" data-start=\"531\" data-end=\"603\"\u003e\u003cspan role=\"text\"\u003eCO₂ Incubator for Precise Cell Culture and Contamination Control\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"340\" data-end=\"545\"\u003eThe \u003cstrong data-start=\"344\" data-end=\"397\"\u003eThermo Scientific™ Forma™ Series II CO₂ Incubator\u003c\/strong\u003e is a precision laboratory incubator designed to maintain \u003cstrong data-start=\"455\" data-end=\"503\"\u003estable temperature, humidity, and CO₂ levels\u003c\/strong\u003e for cell culture and biological research.\u003c\/p\u003e\n\u003cp data-start=\"547\" data-end=\"794\"\u003eIt uses a \u003cstrong data-start=\"557\" data-end=\"650\"\u003ewater jacket heating system, infrared (IR) CO₂ sensor, and continuous HEPA air filtration\u003c\/strong\u003e to create a controlled, contamination-resistant environment—ensuring consistent and reproducible results for sensitive laboratory applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1k9c3xj\" data-start=\"801\" data-end=\"837\"\u003e\u003cspan role=\"text\"\u003eWho This CO₂ Incubator Is For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-section-id=\"jnv98n\" data-start=\"839\" data-end=\"856\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"843\" data-end=\"856\"\u003eBest For:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"857\" data-end=\"1084\"\u003e\n\u003cli data-section-id=\"tpahz5\" data-start=\"857\" data-end=\"901\"\u003eCell culture and tissue engineering labs\u003c\/li\u003e\n\u003cli data-section-id=\"uj3cgw\" data-start=\"902\" data-end=\"952\"\u003eBiotech and pharmaceutical research facilities\u003c\/li\u003e\n\u003cli data-section-id=\"ioejy\" data-start=\"953\" data-end=\"993\"\u003eClinical and diagnostic laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1iqo6ti\" data-start=\"994\" data-end=\"1034\"\u003eIVF and reproductive technology labs\u003c\/li\u003e\n\u003cli data-section-id=\"sp6myl\" data-start=\"1035\" data-end=\"1084\"\u003eAcademic and university research environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-section-id=\"1mrevxz\" data-start=\"1086\" data-end=\"1108\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1090\" data-end=\"1108\"\u003eNot Ideal For:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"1109\" data-end=\"1197\"\u003e\n\u003cli data-section-id=\"1rj0ss9\" data-start=\"1109\" data-end=\"1149\"\u003eBasic incubation without CO₂ control\u003c\/li\u003e\n\u003cli data-section-id=\"1w1d2qw\" data-start=\"1150\" data-end=\"1197\"\u003eLow-complexity or non-critical applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"ztmmtf\" data-start=\"1204\" data-end=\"1243\"\u003e\u003cspan role=\"text\"\u003eKey Features and Why They Matter\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-section-id=\"nlspxk\" data-start=\"1245\" data-end=\"1287\"\u003e\u003cstrong\u003e\u003cspan role=\"text\"\u003eWater Jacket Temperature Stability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1288\" data-end=\"1479\"\u003eThe water jacket system surrounds the chamber with heated water, providing \u003cstrong data-start=\"1363\" data-end=\"1418\"\u003esuperior temperature uniformity and faster recovery\u003c\/strong\u003e after door openings—critical for maintaining cell viability.\u003c\/p\u003e\n\u003cp data-section-id=\"i717cz\" data-start=\"1481\" data-end=\"1524\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1485\" data-end=\"1524\"\u003eInfrared (IR) CO₂ Sensor Technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1525\" data-end=\"1654\"\u003eThe IR sensor delivers \u003cstrong data-start=\"1548\" data-end=\"1586\"\u003eprecise and stable CO₂ measurement\u003c\/strong\u003e, ensuring optimal gas levels for consistent cell growth conditions.\u003c\/p\u003e\n\u003cp data-section-id=\"1twsqp6\" data-start=\"1656\" data-end=\"1697\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1660\" data-end=\"1697\"\u003eContinuous HEPA Filtration System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"1698\" data-end=\"1897\"\u003e\n\u003cli data-section-id=\"iz0pux\" data-start=\"1698\" data-end=\"1749\"\u003eFilters the entire chamber \u003cstrong data-start=\"1727\" data-end=\"1747\"\u003eevery 60 seconds\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"174f7eq\" data-start=\"1750\" data-end=\"1838\"\u003eAchieves \u003cstrong data-start=\"1761\" data-end=\"1817\"\u003eISO Class 5 (Class 100) air quality within 5 minutes\u003c\/strong\u003e after door opening\u003c\/li\u003e\n\u003cli data-section-id=\"1i08y8y\" data-start=\"1839\" data-end=\"1897\"\u003eMinimizes contamination risk in sensitive applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-section-id=\"1a6m21n\" data-start=\"1899\" data-end=\"1931\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1903\" data-end=\"1931\"\u003eTriple Wall Construction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1932\" data-end=\"2047\"\u003eEnhances thermal stability and insulation, ensuring \u003cstrong data-start=\"1984\" data-end=\"2046\"\u003econsistent environmental conditions throughout the chamber\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-section-id=\"1pf91ad\" data-start=\"2049\" data-end=\"2084\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2053\" data-end=\"2084\"\u003eHeated Dual Pane Glass Door\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2085\" data-end=\"2196\"\u003eReduces condensation buildup while allowing clear visibility of samples without disrupting internal conditions.\u003c\/p\u003e\n\u003cp data-section-id=\"sq4erm\" data-start=\"2198\" data-end=\"2230\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2202\" data-end=\"2230\"\u003eUniform Air Distribution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2231\" data-end=\"2354\"\u003eAn internal fan gently circulates air to maintain \u003cstrong data-start=\"2281\" data-end=\"2334\"\u003ehomogeneous temperature, humidity, and CO₂ levels\u003c\/strong\u003e across all shelves.\u003c\/p\u003e\n\u003cp data-section-id=\"ligaed\" data-start=\"2356\" data-end=\"2402\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2360\" data-end=\"2402\"\u003eEasy-to-Clean Stainless Steel Interior\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"2403\" data-end=\"2557\"\u003e\n\u003cli data-section-id=\"1ok3fqg\" data-start=\"2403\" data-end=\"2481\"\u003ePolished stainless steel with coved corners prevents contamination buildup\u003c\/li\u003e\n\u003cli data-section-id=\"1qjclqp\" data-start=\"2482\" data-end=\"2557\"\u003eRemovable shelves and humidity pan allow quick cleaning and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-section-id=\"a521e9\" data-start=\"2559\" data-end=\"2607\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2563\" data-end=\"2607\"\u003eAdvanced Digital Controls and Monitoring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"2608\" data-end=\"2763\"\u003e\n\u003cli data-section-id=\"9to5cw\" data-start=\"2608\" data-end=\"2655\"\u003eAlphanumeric LED display for easy operation\u003c\/li\u003e\n\u003cli data-section-id=\"15vzdij\" data-start=\"2656\" data-end=\"2712\"\u003eReal-time process monitoring and alarm notifications\u003c\/li\u003e\n\u003cli data-section-id=\"1ulkzrg\" data-start=\"2713\" data-end=\"2763\"\u003eConfigurable access control and alert settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"id1bjs\" data-start=\"2770\" data-end=\"2801\"\u003e\u003cspan role=\"text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2803\" data-end=\"3486\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2803\" data-end=\"2830\"\u003e\n\u003ctr data-start=\"2803\" data-end=\"2830\"\u003e\n\u003cth data-start=\"2803\" data-end=\"2819\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2819\" data-end=\"2830\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2849\" data-end=\"3486\"\u003e\n\u003ctr data-start=\"2849\" data-end=\"2900\"\u003e\n\u003ctd data-start=\"2849\" data-end=\"2861\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2851\" data-end=\"2860\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2861\" data-end=\"2900\" data-col-size=\"sm\"\u003eThermo Scientific™ Forma™ Series II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2901\" data-end=\"2941\"\u003e\n\u003ctd data-start=\"2901\" data-end=\"2920\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2903\" data-end=\"2919\"\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2920\" data-end=\"2941\" data-col-size=\"sm\"\u003eThermo Scientific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2942\" data-end=\"2977\"\u003e\n\u003ctd data-start=\"2942\" data-end=\"2960\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2944\" data-end=\"2959\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2960\" data-end=\"2977\" data-col-size=\"sm\"\u003eCO₂ Incubator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2978\" data-end=\"3021\"\u003e\n\u003ctd data-start=\"2978\" data-end=\"2993\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2980\" data-end=\"2992\"\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2993\" data-end=\"3021\" data-col-size=\"sm\"\u003e6.5 cu. ft. \/ 184 Liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3022\" data-end=\"3066\"\u003e\n\u003ctd data-start=\"3022\" data-end=\"3039\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3024\" data-end=\"3038\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3039\" data-end=\"3066\"\u003e20\" x 21-1\/3\" x 26-4\/5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3067\" data-end=\"3116\"\u003e\n\u003ctd data-start=\"3067\" data-end=\"3091\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3069\" data-end=\"3090\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3091\" data-end=\"3116\"\u003eAmbient +5°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3117\" data-end=\"3151\"\u003e\n\u003ctd data-start=\"3117\" data-end=\"3134\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3119\" data-end=\"3133\"\u003eCO₂ Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3134\" data-end=\"3151\" data-col-size=\"sm\"\u003eInfrared (IR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3152\" data-end=\"3183\"\u003e\n\u003ctd data-start=\"3152\" data-end=\"3167\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3154\" data-end=\"3166\"\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3167\" data-end=\"3183\"\u003e\u0026lt;90% at 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3184\" data-end=\"3241\"\u003e\n\u003ctd data-start=\"3184\" data-end=\"3201\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3186\" data-end=\"3200\"\u003eFiltration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3201\" data-end=\"3241\" data-col-size=\"sm\"\u003eHEPA (full chamber every 60 seconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3242\" data-end=\"3287\"\u003e\n\u003ctd data-start=\"3242\" data-end=\"3260\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3244\" data-end=\"3259\"\u003eAir Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3260\" data-end=\"3287\"\u003eISO Class 5 (Class 100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3288\" data-end=\"3336\"\u003e\n\u003ctd data-start=\"3288\" data-end=\"3307\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3290\" data-end=\"3306\"\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3307\" data-end=\"3336\"\u003eWater Jacket, Triple Wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3337\" data-end=\"3371\"\u003e\n\u003ctd data-start=\"3337\" data-end=\"3352\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3339\" data-end=\"3351\"\u003eInterior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3352\" data-end=\"3371\" data-col-size=\"sm\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3372\" data-end=\"3401\"\u003e\n\u003ctd data-start=\"3372\" data-end=\"3384\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3374\" data-end=\"3383\"\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3384\" data-end=\"3401\" data-col-size=\"sm\"\u003e120V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3402\" data-end=\"3432\"\u003e\n\u003ctd data-start=\"3402\" data-end=\"3420\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3404\" data-end=\"3419\"\u003eUNSPSC Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3420\" data-end=\"3432\" data-col-size=\"sm\"\u003e41104407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3433\" data-end=\"3459\"\u003e\n\u003ctd data-start=\"3433\" data-end=\"3453\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3435\" data-end=\"3452\"\u003eBAA Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3453\" data-end=\"3459\" data-col-size=\"sm\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3460\" data-end=\"3486\"\u003e\n\u003ctd data-start=\"3460\" data-end=\"3480\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3462\" data-end=\"3479\"\u003eTAA Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3480\" data-end=\"3486\" data-col-size=\"sm\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"604\" data-end=\"657\"\u003e \u003c\/p\u003e\n\u003ch2 data-section-id=\"pw94wx\" data-start=\"3493\" data-end=\"3528\"\u003e\u003cspan role=\"text\"\u003eHow to Use the CO₂ Incubator\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1vobsgb\" data-start=\"3530\" data-end=\"3618\"\u003e\n\u003cstrong data-start=\"3533\" data-end=\"3549\"\u003eLoad Samples\u003c\/strong\u003e\u003cbr data-start=\"3549\" data-end=\"3552\"\u003ePlace culture vessels or biological samples inside the chamber.\u003c\/li\u003e\n\u003cli data-section-id=\"1y2ocon\" data-start=\"3620\" data-end=\"3731\"\u003e\n\u003cstrong data-start=\"3623\" data-end=\"3655\"\u003eSet Environmental Parameters\u003c\/strong\u003e\u003cbr data-start=\"3655\" data-end=\"3658\"\u003eConfigure temperature, CO₂ levels, and alarms using the control panel.\u003c\/li\u003e\n\u003cli data-section-id=\"muqtn9\" data-start=\"3733\" data-end=\"3827\"\u003e\n\u003cstrong data-start=\"3736\" data-end=\"3756\"\u003eStart Incubation\u003c\/strong\u003e\u003cbr data-start=\"3756\" data-end=\"3759\"\u003eThe incubator automatically maintains stable internal conditions.\u003c\/li\u003e\n\u003cli data-section-id=\"yahoy2\" data-start=\"3829\" data-end=\"3939\"\u003e\n\u003cstrong data-start=\"3832\" data-end=\"3854\"\u003eMonitor and Adjust\u003c\/strong\u003e\u003cbr data-start=\"3854\" data-end=\"3857\"\u003eUse the display and alerts to track performance and make adjustments if needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rovvoz\" data-start=\"3946\" data-end=\"3995\"\u003e\u003cspan role=\"text\"\u003eContamination Control and Clean Air System\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3997\" data-end=\"4095\"\u003eThis incubator is designed to maintain a \u003cstrong data-start=\"4038\" data-end=\"4094\"\u003eclean, controlled environment for sensitive cultures\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"4097\" data-end=\"4337\"\u003e\n\u003cli data-section-id=\"1o5wy5m\" data-start=\"4097\" data-end=\"4152\"\u003eHEPA filtration cleans chamber air every 60 seconds\u003c\/li\u003e\n\u003cli data-section-id=\"1lg5m7a\" data-start=\"4153\" data-end=\"4216\"\u003eRapid recovery to cleanroom air quality after door openings\u003c\/li\u003e\n\u003cli data-section-id=\"182tpx2\" data-start=\"4217\" data-end=\"4278\"\u003eStainless steel interior minimizes contamination surfaces\u003c\/li\u003e\n\u003cli data-section-id=\"19rk9ir\" data-start=\"4279\" data-end=\"4337\"\u003eControlled humidity supports optimal biological growth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"k0zlak\" data-start=\"4344\" data-end=\"4363\"\u003e\u003cspan role=\"text\"\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4365\" data-end=\"4562\"\u003e\n\u003cli data-section-id=\"v6w9dx\" data-start=\"4365\" data-end=\"4391\"\u003eMammalian cell culture\u003c\/li\u003e\n\u003cli data-section-id=\"1uoy7v4\" data-start=\"4392\" data-end=\"4440\"\u003eTissue engineering and regenerative medicine\u003c\/li\u003e\n\u003cli data-section-id=\"o6646j\" data-start=\"4441\" data-end=\"4483\"\u003eMicrobiology and life science research\u003c\/li\u003e\n\u003cli data-section-id=\"1s1xbcq\" data-start=\"4484\" data-end=\"4519\"\u003eIVF and reproductive technology\u003c\/li\u003e\n\u003cli data-section-id=\"mr7fd5\" data-start=\"4520\" data-end=\"4562\"\u003ePharmaceutical and biotech development\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Scientific","offers":[{"title":"Default Title","offer_id":44310479306845,"sku":"1284001","price":21177.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/thermo-scientific-forma-series-ii-co-incubator-6-5-cu-ft-water-jacket-model-3120-1284001-1229490036.jpg?v=1774568469","url":"https:\/\/labequipmentdirect.com\/products\/thermo-forma-series-ii-co2-incubator-6-5-cu-ft","provider":"Lab Equipment Direct","version":"1.0","type":"link"}