{"product_id":"siemens-dca-vantage-hba1c-analyzer","title":"Siemens DCA Vantage Diabetes Management Analyzer – CLIA Waived HbA1c \u0026 A:C Ratio System","description":"\u003ch2 data-end=\"639\" data-start=\"565\" data-section-id=\"tvmi5u\"\u003e\u003cspan role=\"text\"\u003eCLIA Waived HbA1c Analyzer for Fast Point-of-Care Diabetes Testing\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"345\" data-end=\"521\"\u003eThe \u003cstrong data-start=\"349\" data-end=\"402\"\u003eSiemens DCA Vantage® Diabetes Management Analyzer\u003c\/strong\u003e is a compact benchtop system designed for \u003cstrong data-start=\"445\" data-end=\"520\"\u003epoint-of-care HbA1c and urine albumin-to-creatinine (A:C) ratio testing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"523\" data-end=\"769\"\u003eIt uses \u003cstrong data-start=\"531\" data-end=\"594\"\u003eimmunoassay cartridge technology with automatic calibration\u003c\/strong\u003e to deliver clinically accurate results in minutes, helping healthcare providers assess long-term glucose control and detect early kidney disease using minimal sample volumes.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p7kup9\" data-start=\"776\" data-end=\"816\"\u003e\u003cspan role=\"text\"\u003eWho This Diabetes Analyzer Is For\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-section-id=\"jnv98n\" data-start=\"818\" data-end=\"835\"\u003e\u003cspan role=\"text\"\u003eBest For:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"836\" data-end=\"1067\"\u003e\n\u003cli data-section-id=\"1w9zrly\" data-start=\"836\" data-end=\"882\"\u003ePhysician offices and primary care clinics\u003c\/li\u003e\n\u003cli data-section-id=\"1w9g2r\" data-start=\"883\" data-end=\"926\"\u003eEndocrinology and diabetes care centers\u003c\/li\u003e\n\u003cli data-section-id=\"bjn4zs\" data-start=\"927\" data-end=\"965\"\u003ePoint-of-care testing environments\u003c\/li\u003e\n\u003cli data-section-id=\"123x1ch\" data-start=\"966\" data-end=\"1017\"\u003eClinics requiring \u003cstrong data-start=\"986\" data-end=\"1015\"\u003eCLIA waived HbA1c testing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dxri5m\" data-start=\"1018\" data-end=\"1067\"\u003eFacilities focused on fast patient turnaround\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1mrevxz\" data-start=\"1069\" data-end=\"1091\"\u003e\u003cspan role=\"text\"\u003eNot Ideal For:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1092\" data-end=\"1172\"\u003e\n\u003cli data-section-id=\"154h5pz\" data-start=\"1092\" data-end=\"1132\"\u003eHigh-volume centralized laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"p8db7t\" data-start=\"1133\" data-end=\"1172\"\u003eMulti-analyte automated lab systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"jfbjpw\" data-start=\"1179\" data-end=\"1215\"\u003e\u003cspan role=\"text\"\u003eCore Tests and Clinical Value\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1elwjrb\" data-start=\"1217\" data-end=\"1257\"\u003e\u003cspan role=\"text\"\u003eHbA1c Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1258\" data-end=\"1410\"\u003eProvides HbA1c results in approximately \u003cstrong data-start=\"1298\" data-end=\"1311\"\u003e6 minutes\u003c\/strong\u003e, enabling clinicians to evaluate long-term glucose control and make immediate treatment decisions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1b1s8co\" data-start=\"1412\" data-end=\"1480\"\u003e\u003cspan role=\"text\"\u003eAlbumin-to-Creatinine (A:C) Ratio Testing (7-Minute Results)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1481\" data-end=\"1595\"\u003eDetects early kidney damage in diabetic patients, supporting \u003cstrong data-start=\"1542\" data-end=\"1594\"\u003eearly intervention and improved patient outcomes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"8tmzq1\" data-start=\"1597\" data-end=\"1644\"\u003e\u003cspan role=\"text\"\u003eComprehensive Diabetes Monitoring Panel\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1645\" data-end=\"1654\"\u003eSupports:\u003c\/p\u003e\n\u003cul data-start=\"1655\" data-end=\"1749\"\u003e\n\u003cli data-section-id=\"19dycyd\" data-start=\"1655\" data-end=\"1673\"\u003eHemoglobin A1c\u003c\/li\u003e\n\u003cli data-section-id=\"3nv0vs\" data-start=\"1674\" data-end=\"1685\"\u003eAlbumin\u003c\/li\u003e\n\u003cli data-section-id=\"i0kbky\" data-start=\"1686\" data-end=\"1702\"\u003eMicroalbumin\u003c\/li\u003e\n\u003cli data-section-id=\"1t9eqfg\" data-start=\"1703\" data-end=\"1717\"\u003eCreatinine\u003c\/li\u003e\n\u003cli data-section-id=\"1i72wli\" data-start=\"1718\" data-end=\"1749\"\u003eAlbumin-to-Creatinine ratio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1790\" data-start=\"1756\" data-section-id=\"55f9h4\"\u003e\u003cspan role=\"text\"\u003eSpeed and Sample Efficiency\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-end=\"1941\" data-start=\"1792\"\u003e\n\u003cli data-end=\"1825\" data-start=\"1792\" data-section-id=\"y8c78k\"\u003e\n\u003cstrong data-end=\"1812\" data-start=\"1794\"\u003eHbA1c Results:\u003c\/strong\u003e ~6 minutes\u003c\/li\u003e\n\u003cli data-end=\"1863\" data-start=\"1826\" data-section-id=\"1b8js11\"\u003e\n\u003cstrong data-end=\"1850\" data-start=\"1828\"\u003eA:C Ratio Results:\u003c\/strong\u003e ~7 minutes\u003c\/li\u003e\n\u003cli data-end=\"1941\" data-start=\"1864\" data-section-id=\"j9yrtq\"\u003e\n\u003cstrong data-end=\"1884\" data-start=\"1866\"\u003eSample Volume:\u003c\/strong\u003e\n\u003cul data-end=\"1941\" data-start=\"1889\"\u003e\n\u003cli data-end=\"1917\" data-start=\"1889\" data-section-id=\"11r8y97\"\u003e1 µL whole blood (HbA1c)\u003c\/li\u003e\n\u003cli data-end=\"1941\" data-start=\"1920\" data-section-id=\"gb2bk9\"\u003e40 µL urine (A:C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2071\" data-start=\"2040\" data-section-id=\"1o1fi2t\"\u003e\u003cspan role=\"text\"\u003eWorkflow and Ease of Use\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-end=\"2131\" data-start=\"2073\" data-section-id=\"1ddra8\"\u003e\u003cspan role=\"text\"\u003eCartridge-Based Testing with Automatic Calibration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2273\" data-start=\"2132\"\u003e\n\u003cli data-end=\"2216\" data-start=\"2132\" data-section-id=\"eonhw\"\u003eEach test uses an immunoassay cartridge with a \u003cstrong data-end=\"2214\" data-start=\"2181\"\u003elot-specific calibration card\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2273\" data-start=\"2217\" data-section-id=\"oxdaio\"\u003eEliminates manual calibration and reduces user error\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2307\" data-start=\"2275\" data-section-id=\"1h63f5b\"\u003e\u003cspan role=\"text\"\u003eSimple, Guided Operation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2440\" data-start=\"2308\"\u003e\n\u003cli data-end=\"2339\" data-start=\"2308\" data-section-id=\"i36sah\"\u003eColor touchscreen interface\u003c\/li\u003e\n\u003cli data-end=\"2396\" data-start=\"2340\" data-section-id=\"11dfg8u\"\u003eBarcode reader for patient and sample identification\u003c\/li\u003e\n\u003cli data-end=\"2440\" data-start=\"2397\" data-section-id=\"1e557nw\"\u003eMinimal training required for operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2485\" data-start=\"2442\" data-section-id=\"mzzs33\"\u003e\u003cspan role=\"text\"\u003eBuilt-In Printing and Data Handling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2619\" data-start=\"2486\"\u003e\n\u003cli data-end=\"2540\" data-start=\"2486\" data-section-id=\"czc1px\"\u003eOnboard thermal printer provides immediate results\u003c\/li\u003e\n\u003cli data-end=\"2619\" data-start=\"2541\" data-section-id=\"z8jsja\"\u003eElectronic transmission to LIS or EMR systems reduces transcription errors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"18vfbjc\" data-start=\"2626\" data-end=\"2665\"\u003e\u003cspan role=\"text\"\u003eData Management and Connectivity\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2667\" data-end=\"2833\"\u003e\n\u003cli data-section-id=\"nwdf1v\" data-start=\"2667\" data-end=\"2721\"\u003eStores up to \u003cstrong data-start=\"2682\" data-end=\"2719\"\u003e4,000 patient and control records\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1twjowp\" data-start=\"2722\" data-end=\"2763\"\u003eSupports up to \u003cstrong data-start=\"2739\" data-end=\"2761\"\u003e1,000 operator IDs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1m0my1w\" data-start=\"2764\" data-end=\"2833\"\u003eEnables seamless integration with laboratory and clinical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"id1bjs\" data-start=\"2840\" data-end=\"2871\"\u003e\u003cspan role=\"text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2873\" data-end=\"3634\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2873\" data-end=\"2900\"\u003e\n\u003ctr data-start=\"2873\" data-end=\"2900\"\u003e\n\u003cth data-start=\"2873\" data-end=\"2889\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2889\" data-end=\"2900\" data-col-size=\"md\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2919\" data-end=\"3634\"\u003e\n\u003ctr data-start=\"2919\" data-end=\"2947\"\u003e\n\u003ctd data-start=\"2919\" data-end=\"2931\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2921\" data-end=\"2930\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2931\" data-end=\"2947\" data-col-size=\"md\"\u003eDCA Vantage®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2948\" data-end=\"2978\"\u003e\n\u003ctd data-start=\"2948\" data-end=\"2967\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2950\" data-end=\"2966\"\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2967\" data-end=\"2978\" data-col-size=\"md\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2979\" data-end=\"3029\"\u003e\n\u003ctd data-start=\"2979\" data-end=\"2997\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2981\" data-end=\"2996\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2997\" data-end=\"3029\" data-col-size=\"md\"\u003eDiabetes Management Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3030\" data-end=\"3062\"\u003e\n\u003ctd data-start=\"3030\" data-end=\"3050\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3032\" data-end=\"3049\"\u003eAnalyzer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3050\" data-end=\"3062\" data-col-size=\"md\"\u003eBenchtop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3063\" data-end=\"3134\"\u003e\n\u003ctd data-start=\"3063\" data-end=\"3089\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3065\" data-end=\"3088\"\u003eCLIA Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3089\" data-end=\"3134\" data-col-size=\"md\"\u003eWaived (HbA1c), Moderate Complexity (A:C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3135\" data-end=\"3176\"\u003e\n\u003ctd data-start=\"3135\" data-end=\"3154\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3137\" data-end=\"3153\"\u003eSample Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3154\" data-end=\"3176\" data-col-size=\"md\"\u003eWhole Blood, Urine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3177\" data-end=\"3228\"\u003e\n\u003ctd data-start=\"3177\" data-end=\"3197\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3179\" data-end=\"3196\"\u003eSample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3197\" data-end=\"3228\" data-col-size=\"md\"\u003e1 µL (blood), 40 µL (urine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3229\" data-end=\"3286\"\u003e\n\u003ctd data-start=\"3229\" data-end=\"3245\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3231\" data-end=\"3244\"\u003eTest Menu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3245\" data-end=\"3286\" data-col-size=\"md\"\u003eHbA1c, Albumin, Creatinine, A:C Ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3287\" data-end=\"3339\"\u003e\n\u003ctd data-start=\"3287\" data-end=\"3309\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3289\" data-end=\"3308\"\u003eTime to Results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3309\" data-end=\"3339\" data-col-size=\"md\"\u003e6 min (HbA1c), 7 min (A:C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3340\" data-end=\"3375\"\u003e\n\u003ctd data-start=\"3340\" data-end=\"3354\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3342\" data-end=\"3353\"\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3354\" data-end=\"3375\" data-col-size=\"md\"\u003eColor Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3376\" data-end=\"3418\"\u003e\n\u003ctd data-start=\"3376\" data-end=\"3390\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3378\" data-end=\"3389\"\u003ePrinter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3390\" data-end=\"3418\" data-col-size=\"md\"\u003eBuilt-in Thermal Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3419\" data-end=\"3458\"\u003e\n\u003ctd data-start=\"3419\" data-end=\"3436\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3421\" data-end=\"3435\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3436\" data-end=\"3458\" data-col-size=\"md\"\u003e9\" x 10\" x 11-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3459\" data-end=\"3481\"\u003e\n\u003ctd data-start=\"3459\" data-end=\"3472\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3461\" data-end=\"3471\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3472\" data-end=\"3481\" data-col-size=\"md\"\u003e9 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3482\" data-end=\"3509\"\u003e\n\u003ctd data-start=\"3482\" data-end=\"3494\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3484\" data-end=\"3493\"\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3494\" data-end=\"3509\" data-col-size=\"md\"\u003e100–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3510\" data-end=\"3548\"\u003e\n\u003ctd data-start=\"3510\" data-end=\"3523\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3512\" data-end=\"3522\"\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3523\" data-end=\"3548\" data-col-size=\"md\"\u003e4,000 patient records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3549\" data-end=\"3579\"\u003e\n\u003ctd data-start=\"3549\" data-end=\"3567\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3551\" data-end=\"3566\"\u003eUNSPSC Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3567\" data-end=\"3579\" data-col-size=\"md\"\u003e41115819\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3580\" data-end=\"3606\"\u003e\n\u003ctd data-start=\"3580\" data-end=\"3600\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3582\" data-end=\"3599\"\u003eBAA Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3600\" data-end=\"3606\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3607\" data-end=\"3634\"\u003e\n\u003ctd data-start=\"3607\" data-end=\"3627\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3609\" data-end=\"3626\"\u003eTAA Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3627\" data-end=\"3634\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"702\" data-start=\"640\"\u003e \u003c\/p\u003e\n\u003ch2 data-section-id=\"z9d0mc\" data-start=\"3641\" data-end=\"3691\"\u003e\u003cspan role=\"text\"\u003eHow the Siemens DCA Vantage® Analyzer Works\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"3696\" data-end=\"3714\"\u003eCollect Sample\u003c\/strong\u003e\u003cbr data-start=\"3714\" data-end=\"3717\"\u003eObtain a small blood or urine sample.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"3762\" data-end=\"3787\"\u003eInsert Test Cartridge\u003c\/strong\u003e\u003cbr data-start=\"3787\" data-end=\"3790\"\u003eLoad the immunoassay cartridge with calibration card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"3851\" data-end=\"3869\"\u003eStart Analysis\u003c\/strong\u003e\u003cbr data-start=\"3869\" data-end=\"3872\"\u003eThe analyzer automatically processes the sample.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"3928\" data-end=\"3944\"\u003eView Results\u003c\/strong\u003e\u003cbr data-start=\"3944\" data-end=\"3947\"\u003eResults are displayed and printed within minutes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1xayc77\" data-start=\"4006\" data-end=\"4034\"\u003e\u003cspan role=\"text\"\u003eClinical Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4036\" data-end=\"4244\"\u003e\n\u003cli data-section-id=\"1ibcuth\" data-start=\"4036\" data-end=\"4073\"\u003eDiabetes diagnosis and monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"i1mi42\" data-start=\"4074\" data-end=\"4113\"\u003eGlycemic control assessment (HbA1c)\u003c\/li\u003e\n\u003cli data-section-id=\"19cw1ds\" data-start=\"4114\" data-end=\"4160\"\u003eEarly detection of diabetic kidney disease\u003c\/li\u003e\n\u003cli data-section-id=\"1b0b6rl\" data-start=\"4161\" data-end=\"4207\"\u003eRoutine screening in primary care settings\u003c\/li\u003e\n\u003cli data-section-id=\"1730d4o\" data-start=\"4208\" data-end=\"4244\"\u003ePoint-of-care patient management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1onauyg\" data-start=\"4251\" data-end=\"4293\"\u003e\u003cspan role=\"text\"\u003eCompliance and Laboratory Standards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4295\" data-end=\"4494\"\u003e\n\u003cli data-section-id=\"1ddlsyb\" data-start=\"4295\" data-end=\"4332\"\u003e\u003cstrong data-start=\"4297\" data-end=\"4330\"\u003eCLIA Waived for HbA1c testing\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1rlh4jj\" data-start=\"4333\" data-end=\"4381\"\u003e\u003cstrong data-start=\"4335\" data-end=\"4379\"\u003eCLIA Moderate Complexity for A:C testing\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1u7fxci\" data-start=\"4382\" data-end=\"4438\"\u003eDesigned for point-of-care and clinical environments\u003c\/li\u003e\n\u003cli data-section-id=\"1dwjdrx\" data-start=\"4439\" data-end=\"4494\"\u003eSupports standardized diabetes monitoring protocols\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"DCA Vantage","offers":[{"title":"Default Title","offer_id":44312131436637,"sku":"641021","price":4664.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/siemens-dca-vantage-diabetes-management-analyzer-clia-waived-hba1c-a-c-ratio-system-641021-1229606824.jpg?v=1774640469","url":"https:\/\/labequipmentdirect.com\/products\/siemens-dca-vantage-hba1c-analyzer","provider":"Lab Equipment Direct","version":"1.0","type":"link"}