{"product_id":"manual-large-capacity-autoclave-3870m","title":"Tuttnauer USA Manual Large-Capacity Autoclave 3870M","description":"\u003ch2 data-section-id=\"1jwmkg\" data-start=\"172\" data-end=\"246\"\u003eHigh-Capacity Manual Autoclave for Clinics, Surgery Centers \u0026amp; Labs\u003c\/h2\u003e\n\u003cp data-start=\"753\" data-end=\"1021\"\u003eThe \u003cstrong data-start=\"757\" data-end=\"783\"\u003e3870M manual autoclave\u003c\/strong\u003e is designed for clinics and labs that need \u003cstrong data-start=\"827\" data-end=\"885\"\u003ehigh-capacity sterilization without complex automation\u003c\/strong\u003e. With an \u003cstrong data-start=\"895\" data-end=\"910\"\u003e85L chamber\u003c\/strong\u003e, it supports large instrument loads and long tools while maintaining reliable, compliant sterilization cycles.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1uh54sf\" data-start=\"1028\" data-end=\"1085\"\u003eIs the 3870M the Right Autoclave for Your Facility?\u003c\/h2\u003e\n\u003ch3 data-section-id=\"pnxjaz\" data-start=\"1087\" data-end=\"1104\"\u003e\n\u003cstrong\u003e✅ \u003c\/strong\u003eBest Fit\u003c\/h3\u003e\n\u003cp data-start=\"1105\" data-end=\"1129\"\u003e\u003cstrong\u003eChoose the 3870M if you:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1131\" data-end=\"1401\"\u003e\n\u003cli data-section-id=\"ep52d7\" data-start=\"1131\" data-end=\"1186\"\u003eRun a \u003cstrong data-start=\"1139\" data-end=\"1186\"\u003emulti-practitioner clinic or surgery center\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oufyhf\" data-start=\"1187\" data-end=\"1235\"\u003eProcess \u003cstrong data-start=\"1197\" data-end=\"1235\"\u003elarge volumes of instruments daily\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16oftav\" data-start=\"1236\" data-end=\"1288\"\u003eNeed to sterilize \u003cstrong data-start=\"1256\" data-end=\"1288\"\u003elong instruments (up to 30”)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xj7ogo\" data-start=\"1289\" data-end=\"1351\"\u003ePrefer a \u003cstrong data-start=\"1300\" data-end=\"1351\"\u003emanual system with lower maintenance complexity\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"sb9z5\" data-start=\"1352\" data-end=\"1401\"\u003eRequire \u003cstrong data-start=\"1362\" data-end=\"1401\"\u003eFDA and ISO-compliant sterilization\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-section-id=\"1ci6lq9\" data-start=\"1408\" data-end=\"1431\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e\u003c\/span\u003eA \u003cstrong data-start=\"3558\" data-end=\"3591\"\u003e0.5KVA buck\/boost transformer\u003c\/strong\u003e may be required depending on your facility’s electrical setup.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ci6lq9\" data-start=\"1408\" data-end=\"1431\"\u003e⚠️ Not Ideal For\u003c\/h2\u003e\n\u003cp data-start=\"1432\" data-end=\"1476\"\u003eThis unit may NOT be the best choice if you:\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1695\"\u003e\n\u003cli data-section-id=\"1m5s4bx\" data-start=\"1478\" data-end=\"1517\"\u003eOperate a \u003cstrong data-start=\"1490\" data-end=\"1517\"\u003elow-volume or small lab\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bamdc8\" data-start=\"1518\" data-end=\"1580\"\u003eNeed \u003cstrong data-start=\"1525\" data-end=\"1580\"\u003efully automated cycle tracking or digital reporting\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vql5po\" data-start=\"1581\" data-end=\"1653\"\u003eHave \u003cstrong data-start=\"1588\" data-end=\"1653\"\u003elimited space or lower power availability (requires 220–235V)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"p2uk0e\" data-start=\"1654\" data-end=\"1695\"\u003ePrefer \u003cstrong data-start=\"1663\" data-end=\"1695\"\u003ecompact tabletop sterilizers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"ysch0n\" data-start=\"156\" data-end=\"178\"\u003eKey Capabilities\u003c\/h2\u003e\n\u003cul data-start=\"180\" data-end=\"1058\"\u003e\n\u003cli data-section-id=\"ecejf3\" data-start=\"180\" data-end=\"312\"\u003e\n\u003cstrong data-start=\"182\" data-end=\"214\"\u003eLarge-Capacity Chamber (85L)\u003c\/strong\u003e\u003cbr data-start=\"214\" data-end=\"217\"\u003eAccommodates long instruments and bulk loads, with capacity for up to 15 full-size cassettes.\u003c\/li\u003e\n\u003cli data-section-id=\"1xo1tfw\" data-start=\"314\" data-end=\"453\"\u003e\n\u003cstrong data-start=\"316\" data-end=\"343\"\u003eSimple Manual Operation\u003c\/strong\u003e\u003cbr data-start=\"343\" data-end=\"346\"\u003eNo complex programming required, making it ideal for facilities prioritizing ease of use and reliability.\u003c\/li\u003e\n\u003cli data-section-id=\"15l9imq\" data-start=\"455\" data-end=\"599\"\u003e\n\u003cstrong data-start=\"457\" data-end=\"485\"\u003eAutomatic Cycle Shut-Off\u003c\/strong\u003e\u003cbr data-start=\"485\" data-end=\"488\"\u003eAutomatically stops at the end of sterilization and drying cycles, reducing the need for constant monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"1cl278c\" data-start=\"601\" data-end=\"760\"\u003e\n\u003cstrong data-start=\"603\" data-end=\"633\"\u003eBuilt-In Safety Protection\u003c\/strong\u003e\u003cbr data-start=\"633\" data-end=\"636\"\u003eDouble safety locking system prevents opening under pressure, while a dual safety thermostat protects against overheating.\u003c\/li\u003e\n\u003cli data-section-id=\"14ka7yo\" data-start=\"762\" data-end=\"902\"\u003e\n\u003cstrong data-start=\"764\" data-end=\"799\"\u003eDurable, Long-Life Construction\u003c\/strong\u003e\u003cbr data-start=\"799\" data-end=\"802\"\u003eElectro-polished chamber and door resist corrosion and are designed for consistent, long-term use.\u003c\/li\u003e\n\u003cli data-section-id=\"15zknh2\" data-start=\"904\" data-end=\"1058\"\u003e\n\u003cstrong data-start=\"906\" data-end=\"937\"\u003eMaintenance-Friendly Design\u003c\/strong\u003e\u003cbr data-start=\"937\" data-end=\"940\"\u003eFront-facing drain valve allows quick reservoir drainage, and the included 3-shelf stand supports organized storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"10k15yz\" data-start=\"2985\" data-end=\"3015\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3017\" data-end=\"3537\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3017\" data-end=\"3044\"\u003e\n\u003ctr data-start=\"3017\" data-end=\"3044\"\u003e\n\u003cth data-start=\"3017\" data-end=\"3033\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3033\" data-end=\"3044\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3063\" data-end=\"3537\"\u003e\n\u003ctr data-start=\"3063\" data-end=\"3110\"\u003e\n\u003ctd data-start=\"3063\" data-end=\"3084\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3065\" data-end=\"3083\"\u003eChamber Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3084\" data-end=\"3110\" data-col-size=\"sm\"\u003e85 Liters (22 Gallons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3111\" data-end=\"3149\"\u003e\n\u003ctd data-start=\"3111\" data-end=\"3136\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3113\" data-end=\"3135\"\u003eChamber Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3136\" data-end=\"3149\" data-col-size=\"sm\"\u003e15” x 30”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3150\" data-end=\"3198\"\u003e\n\u003ctd data-start=\"3150\" data-end=\"3175\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3152\" data-end=\"3174\"\u003eOverall Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3175\" data-end=\"3198\" data-col-size=\"sm\"\u003e34.5” x 26” x 20.6”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3199\" data-end=\"3230\"\u003e\n\u003ctd data-start=\"3199\" data-end=\"3219\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3201\" data-end=\"3218\"\u003eTray Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3219\" data-end=\"3230\" data-col-size=\"sm\"\u003e2 Trays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3231\" data-end=\"3291\"\u003e\n\u003ctd data-start=\"3231\" data-end=\"3248\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3233\" data-end=\"3247\"\u003eTray Sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3248\" data-end=\"3291\" data-col-size=\"sm\"\u003e26.6” x 11.3” x 1” \/ 26.6” x 13.8” x 1”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3292\" data-end=\"3337\"\u003e\n\u003ctd data-start=\"3292\" data-end=\"3316\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3294\" data-end=\"3315\"\u003eCassette Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3316\" data-end=\"3337\" data-col-size=\"sm\"\u003e15 Full Cassettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3338\" data-end=\"3376\"\u003e\n\u003ctd data-start=\"3338\" data-end=\"3364\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3340\" data-end=\"3363\"\u003eVoltage Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3364\" data-end=\"3376\" data-col-size=\"sm\"\u003e220–235V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3377\" data-end=\"3404\"\u003e\n\u003ctd data-start=\"3377\" data-end=\"3393\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3379\" data-end=\"3392\"\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3393\" data-end=\"3404\" data-col-size=\"sm\"\u003e50–60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3405\" data-end=\"3426\"\u003e\n\u003ctd data-start=\"3405\" data-end=\"3417\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3407\" data-end=\"3416\"\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3417\" data-end=\"3426\" data-col-size=\"sm\"\u003e3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3427\" data-end=\"3450\"\u003e\n\u003ctd data-start=\"3427\" data-end=\"3441\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3429\" data-end=\"3440\"\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3441\" data-end=\"3450\" data-col-size=\"sm\"\u003e13.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3451\" data-end=\"3497\"\u003e\n\u003ctd data-start=\"3451\" data-end=\"3473\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3453\" data-end=\"3472\"\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3473\" data-end=\"3497\" data-col-size=\"sm\"\u003e278 lbs (with stand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3498\" data-end=\"3537\"\u003e\n\u003ctd data-start=\"3498\" data-end=\"3513\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3500\" data-end=\"3512\"\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3513\" data-end=\"3537\" data-col-size=\"sm\"\u003e1 Year Parts \u0026amp; Labor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 data-section-id=\"c21xbc\" data-start=\"3855\" data-end=\"3900\"\u003eInstallation \u0026amp; Operational Requirements\u003c\/h2\u003e\n\u003cp data-start=\"3902\" data-end=\"3929\"\u003e\u003cstrong\u003eBefore purchasing, confirm:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3931\" data-end=\"4128\"\u003e\n\u003cli data-section-id=\"g2x9xn\" data-start=\"3931\" data-end=\"3973\"\u003eAccess to \u003cstrong data-start=\"3943\" data-end=\"3973\"\u003e220–235V electrical supply\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ovi9c1\" data-start=\"3974\" data-end=\"4027\"\u003eAdequate space for \u003cstrong data-start=\"3995\" data-end=\"4027\"\u003elarge footprint installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"183bx0i\" data-start=\"4028\" data-end=\"4072\"\u003eProper drainage setup for manual operation\u003c\/li\u003e\n\u003cli data-section-id=\"8zywnm\" data-start=\"4073\" data-end=\"4128\"\u003eStaff trained to operate \u003cstrong data-start=\"4100\" data-end=\"4128\"\u003emanual autoclave systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFailure to meet these requirements can result in:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4180\" data-end=\"4273\"\u003e\n\u003cli data-section-id=\"1i7bfzy\" data-start=\"4180\" data-end=\"4213\"\u003eImproper sterilization cycles\u003c\/li\u003e\n\u003cli data-section-id=\"12becr6\" data-start=\"4214\" data-end=\"4240\"\u003eEquipment inefficiency\u003c\/li\u003e\n\u003cli data-section-id=\"c17qn3\" data-start=\"4241\" data-end=\"4273\"\u003eIncreased maintenance issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"ffd7gl\" data-start=\"3661\" data-end=\"3693\"\u003eCompliance \u0026amp; Certification\u003c\/h2\u003e\n\u003cp data-start=\"3694\" data-end=\"3772\"\u003eThis autoclave is designed to meet current sterilization and safety standards:\u003c\/p\u003e\n\u003cul data-start=\"3774\" data-end=\"3848\"\u003e\n\u003cli data-section-id=\"662wuc\" data-start=\"3774\" data-end=\"3791\"\u003eFDA Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1odcgyl\" data-start=\"3792\" data-end=\"3810\"\u003eISO 13485:2003\u003c\/li\u003e\n\u003cli data-section-id=\"jt6vot\" data-start=\"3811\" data-end=\"3828\"\u003eISO 9001:2000\u003c\/li\u003e\n\u003cli data-section-id=\"sfbym7\" data-start=\"3829\" data-end=\"3848\"\u003eUL \/ EN 61010-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Tuttnauer USA","offers":[{"title":"Default Title","offer_id":44273542463581,"sku":"480011","price":30610.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/tuttnauer-usa-manual-large-capacity-autoclave-3870m-3870eap-1227553285.png?v=1773783731","url":"https:\/\/labequipmentdirect.com\/products\/manual-large-capacity-autoclave-3870m","provider":"Lab Equipment Direct","version":"1.0","type":"link"}