{"product_id":"atellica-ch-930-chemistry-analyzer-clia-non-waived","title":"Siemens Atellica CH 930 Chemistry Analyzer – High-Throughput Clinical Lab System","description":"\u003ch2 data-section-id=\"1qnjlwi\" data-start=\"230\" data-end=\"305\"\u003e\u003cspan role=\"text\"\u003eWhat Is the Atellica® CH 930 Chemistry Analyzer and How Does It Work\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"307\" data-end=\"549\"\u003eThe \u003cstrong data-start=\"311\" data-end=\"350\"\u003eAtellica® CH 930 Chemistry Analyzer\u003c\/strong\u003e is a high-throughput, floorstanding clinical chemistry system designed to perform \u003cstrong data-start=\"433\" data-end=\"482\"\u003eautomated photometric and electrolyte testing\u003c\/strong\u003e across multiple sample types in regulated laboratory environments.\u003c\/p\u003e\n\u003cp data-start=\"551\" data-end=\"853\"\u003eIt uses \u003cstrong data-start=\"559\" data-end=\"689\"\u003emicro-volume photometric technology for chemistry analysis and integrated multisensor technology (IMT) for electrolyte testing\u003c\/strong\u003e, delivering fast, accurate, and consistent results for hospitals, diagnostic laboratories, and high-volume clinical settings requiring \u003cstrong data-start=\"825\" data-end=\"852\"\u003eCLIA non-waived testing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"kdootg\" data-start=\"860\" data-end=\"891\"\u003e\u003cspan role=\"text\"\u003eWho This Analyzer Is For\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-section-id=\"jnv98n\" data-start=\"893\" data-end=\"910\"\u003e\u003cspan role=\"text\"\u003eBest For:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"911\" data-end=\"1125\"\u003e\n\u003cli data-section-id=\"1ynaqat\" data-start=\"911\" data-end=\"955\"\u003eHospital laboratories and reference labs\u003c\/li\u003e\n\u003cli data-section-id=\"sxi4wl\" data-start=\"956\" data-end=\"1014\"\u003eHigh-volume diagnostic and clinical testing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"ayhhcx\" data-start=\"1015\" data-end=\"1067\"\u003eLabs requiring CLIA non-waived chemistry testing\u003c\/li\u003e\n\u003cli data-section-id=\"15mv0nw\" data-start=\"1068\" data-end=\"1125\"\u003eFacilities scaling throughput and automation capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1mrevxz\" data-start=\"1127\" data-end=\"1149\"\u003e\u003cspan role=\"text\"\u003eNot Ideal For:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1150\" data-end=\"1292\"\u003e\n\u003cli data-section-id=\"1jirs4a\" data-start=\"1150\" data-end=\"1194\"\u003eSmall labs with low daily testing volume\u003c\/li\u003e\n\u003cli data-section-id=\"1p132dd\" data-start=\"1195\" data-end=\"1240\"\u003ePoint-of-care or CLIA-waived environments\u003c\/li\u003e\n\u003cli data-section-id=\"1vzpmzb\" data-start=\"1241\" data-end=\"1292\"\u003eFacilities without trained laboratory personnel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"vjm778\" data-start=\"1299\" data-end=\"1351\"\u003e\n\u003cspan role=\"text\"\u003eKey Features and Performance \u003c\/span\u003e\u003cspan role=\"text\"\u003eHigh-Throughput Testing Capacity\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"1394\" data-end=\"1490\"\u003eProcesses \u003cstrong data-start=\"1404\" data-end=\"1434\"\u003eup to 1,800 tests per hour\u003c\/strong\u003e, enabling rapid turnaround in high-demand environments:\u003c\/p\u003e\n\u003cul data-start=\"1491\" data-end=\"1590\"\u003e\n\u003cli data-section-id=\"1h9x7iv\" data-start=\"1491\" data-end=\"1538\"\u003ePhotometric testing: up to 1,200 tests\/hour\u003c\/li\u003e\n\u003cli data-section-id=\"1ekr4lx\" data-start=\"1539\" data-end=\"1590\"\u003eElectrolyte testing (IMT): up to 600 tests\/hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ea0fpz\" data-start=\"1592\" data-end=\"1635\"\u003e\u003cspan role=\"text\"\u003eMicro-Volume Photometric Technology\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1636\" data-end=\"1756\"\u003eDelivers accurate chemistry analysis using minimal sample volume, reducing reagent consumption and improving efficiency.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1w1bv3t\" data-start=\"1758\" data-end=\"1805\"\u003e\u003cspan role=\"text\"\u003eIntegrated Multisensor Technology (IMT)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1806\" data-end=\"1936\"\u003eProvides consistent and reliable electrolyte measurements across different sample types, supporting critical diagnostic workflows.\u003c\/p\u003e\n\u003ch3 data-section-id=\"10bl17u\" data-start=\"1938\" data-end=\"1973\"\u003e\u003cspan role=\"text\"\u003eScalable System Integration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1974\" data-end=\"2130\"\u003eUp to \u003cstrong data-start=\"1980\" data-end=\"2059\"\u003esix Atellica CH 930 analyzers can be connected within the Atellica Solution\u003c\/strong\u003e, allowing laboratories to expand capacity as testing demand increases.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7uhqes\" data-start=\"2132\" data-end=\"2166\"\u003e\u003cspan role=\"text\"\u003eBroad Sample Compatibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2167\" data-end=\"2209\"\u003eSupports a wide range of clinical samples:\u003c\/p\u003e\n\u003cul data-start=\"2210\" data-end=\"2286\"\u003e\n\u003cli data-section-id=\"15o0wd7\" data-start=\"2210\" data-end=\"2225\"\u003eWhole blood\u003c\/li\u003e\n\u003cli data-section-id=\"1v4d5h0\" data-start=\"2226\" data-end=\"2235\"\u003eSerum\u003c\/li\u003e\n\u003cli data-section-id=\"1xmingq\" data-start=\"2236\" data-end=\"2246\"\u003ePlasma\u003c\/li\u003e\n\u003cli data-section-id=\"14xhe5p\" data-start=\"2247\" data-end=\"2256\"\u003eUrine\u003c\/li\u003e\n\u003cli data-section-id=\"1mtjmwa\" data-start=\"2257\" data-end=\"2286\"\u003eCerebrospinal fluid (CSF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"12h32f\" data-start=\"2288\" data-end=\"2316\"\u003e\u003cspan role=\"text\"\u003eExtensive Assay Menu\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2317\" data-end=\"2427\"\u003eEnables comprehensive chemistry testing, supporting routine diagnostics and specialized clinical applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"id1bjs\" data-start=\"2434\" data-end=\"2465\"\u003e\u003cspan role=\"text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2467\" data-end=\"3115\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2467\" data-end=\"2494\"\u003e\n\u003ctr data-start=\"2467\" data-end=\"2494\"\u003e\n\u003cth data-start=\"2467\" data-end=\"2483\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2483\" data-end=\"2494\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2513\" data-end=\"3115\"\u003e\n\u003ctr data-start=\"2513\" data-end=\"2538\"\u003e\n\u003ctd data-start=\"2513\" data-end=\"2525\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2515\" data-end=\"2524\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2525\" data-end=\"2538\" data-col-size=\"sm\"\u003eAtellica®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2539\" data-end=\"2561\"\u003e\n\u003ctd data-start=\"2539\" data-end=\"2551\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2541\" data-end=\"2550\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2551\" data-end=\"2561\" data-col-size=\"sm\"\u003eCH 930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2562\" data-end=\"2592\"\u003e\n\u003ctd data-start=\"2562\" data-end=\"2581\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2564\" data-end=\"2580\"\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2581\" data-end=\"2592\" data-col-size=\"sm\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2593\" data-end=\"2630\"\u003e\n\u003ctd data-start=\"2593\" data-end=\"2613\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2595\" data-end=\"2612\"\u003eAnalyzer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2613\" data-end=\"2630\"\u003eFloorstanding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2631\" data-end=\"2671\"\u003e\n\u003ctd data-start=\"2631\" data-end=\"2649\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2633\" data-end=\"2648\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2649\" data-end=\"2671\" data-col-size=\"sm\"\u003eChemistry Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2672\" data-end=\"2715\"\u003e\n\u003ctd data-start=\"2672\" data-end=\"2689\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2674\" data-end=\"2688\"\u003eThroughput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2689\" data-end=\"2715\" data-col-size=\"sm\"\u003eUp to 1,800 tests\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2716\" data-end=\"2758\"\u003e\n\u003ctd data-start=\"2716\" data-end=\"2738\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2718\" data-end=\"2737\"\u003eSample Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2738\" data-end=\"2758\"\u003e70 Assay Onboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2759\" data-end=\"2820\"\u003e\n\u003ctd data-start=\"2759\" data-end=\"2778\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2761\" data-end=\"2777\"\u003eSample Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2778\" data-end=\"2820\" data-col-size=\"sm\"\u003eWhole Blood, Serum, Plasma, Urine, CSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2821\" data-end=\"2861\"\u003e\n\u003ctd data-start=\"2821\" data-end=\"2837\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2823\" data-end=\"2836\"\u003eTest Menu\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2837\" data-end=\"2861\" data-col-size=\"sm\"\u003eExtensive Assay Menu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2862\" data-end=\"2912\"\u003e\n\u003ctd data-start=\"2862\" data-end=\"2887\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2864\" data-end=\"2886\"\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2887\" data-end=\"2912\" data-col-size=\"sm\"\u003e200–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2913\" data-end=\"2961\"\u003e\n\u003ctd data-start=\"2913\" data-end=\"2930\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2915\" data-end=\"2929\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2930\" data-end=\"2961\" data-col-size=\"sm\"\u003e45-1\/2\" x 53-3\/4\" x 58-3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2962\" data-end=\"2988\"\u003e\n\u003ctd data-start=\"2962\" data-end=\"2975\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2964\" data-end=\"2974\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2975\" data-end=\"2988\" data-col-size=\"sm\"\u003e1,036 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2989\" data-end=\"3029\"\u003e\n\u003ctd data-start=\"2989\" data-end=\"3015\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2991\" data-end=\"3014\"\u003eCLIA Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3015\" data-end=\"3029\" data-col-size=\"sm\"\u003eNon-Waived\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3030\" data-end=\"3057\"\u003e\n\u003ctd data-start=\"3030\" data-end=\"3050\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3032\" data-end=\"3049\"\u003eTAA Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3050\" data-end=\"3057\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3058\" data-end=\"3084\"\u003e\n\u003ctd data-start=\"3058\" data-end=\"3078\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3060\" data-end=\"3077\"\u003eBAA Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3078\" data-end=\"3084\" data-col-size=\"sm\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3085\" data-end=\"3115\"\u003e\n\u003ctd data-start=\"3085\" data-end=\"3103\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3087\" data-end=\"3102\"\u003eUNSPSC Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3103\" data-end=\"3115\" data-col-size=\"sm\"\u003e41115807\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"551\" data-end=\"853\"\u003e \u003c\/p\u003e\n\u003ch2 data-section-id=\"1lq355s\" data-start=\"3122\" data-end=\"3163\"\u003e\u003cspan role=\"text\"\u003eThroughput and Workflow Efficienc\u003cstrong data-start=\"3125\" data-end=\"3163\"\u003ey\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3165\" data-end=\"3266\"\u003eThe Atellica® CH 930 is designed for \u003cstrong data-start=\"3202\" data-end=\"3239\"\u003econtinuous, high-volume operation\u003c\/strong\u003e, allowing laboratories to:\u003c\/p\u003e\n\u003cul data-start=\"3268\" data-end=\"3474\"\u003e\n\u003cli data-section-id=\"1wpskce\" data-start=\"3268\" data-end=\"3312\"\u003eProcess large sample batches efficiently\u003c\/li\u003e\n\u003cli data-section-id=\"1svvvad\" data-start=\"3313\" data-end=\"3362\"\u003eReduce turnaround time for diagnostic results\u003c\/li\u003e\n\u003cli data-section-id=\"8i5tdq\" data-start=\"3363\" data-end=\"3423\"\u003eMaintain consistent performance across varying workloads\u003c\/li\u003e\n\u003cli data-section-id=\"1atlj0c\" data-start=\"3424\" data-end=\"3474\"\u003eScale operations without compromising accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1m1ziwb\" data-start=\"3958\" data-end=\"4001\"\u003e\u003cspan role=\"text\"\u003eClinical and Laboratory Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4003\" data-end=\"4176\"\u003e\n\u003cli data-section-id=\"m9n13d\" data-start=\"4003\" data-end=\"4041\"\u003eRoutine clinical chemistry testing\u003c\/li\u003e\n\u003cli data-section-id=\"e93wjc\" data-start=\"4042\" data-end=\"4066\"\u003eElectrolyte analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1prxm6z\" data-start=\"4067\" data-end=\"4100\"\u003eHospital diagnostic workflows\u003c\/li\u003e\n\u003cli data-section-id=\"zb0qc6\" data-start=\"4101\" data-end=\"4133\"\u003eReference laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"1igb5tg\" data-start=\"4134\" data-end=\"4176\"\u003eHigh-throughput screening and analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"wtl5o3\" data-start=\"4183\" data-end=\"4219\"\u003e\u003cspan role=\"text\"\u003eCompliance and Laboratory Use\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4221\" data-end=\"4410\"\u003e\n\u003cli data-section-id=\"198yx58\" data-start=\"4221\" data-end=\"4295\"\u003e\n\u003cstrong data-start=\"4223\" data-end=\"4247\"\u003eCLIA Classification:\u003c\/strong\u003e Non-waived (requires certified lab personnel)\u003c\/li\u003e\n\u003cli data-section-id=\"139i1pz\" data-start=\"4296\" data-end=\"4355\"\u003eDesigned for regulated clinical laboratory environments\u003c\/li\u003e\n\u003cli data-section-id=\"51gsnd\" data-start=\"4356\" data-end=\"4410\"\u003eSupports standardized diagnostic testing protocols\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atellica","offers":[{"title":"Default Title","offer_id":44312429428829,"sku":"1109703","price":241163.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/6866\/0573\/files\/siemens-atellica-ch-930-chemistry-analyzer-high-throughput-clinical-lab-system-1109703-1229623713.jpg?v=1774654869","url":"https:\/\/labequipmentdirect.com\/products\/atellica-ch-930-chemistry-analyzer-clia-non-waived","provider":"Lab Equipment Direct","version":"1.0","type":"link"}